RxControl: Communication > Input/Output Selection
Use these commands to define/inquire the type of data that the receiver should accept/send
on a given connection descriptor (
Cd
- see 1.1.5 ).
The
Input
argument is used to tell the receiver how to interpret incoming bytes on the connec-
tion
Cd
. If a connection is to be used for receiving user commands or differential corrections
in RTCM or CMR format, it is recommended to leave it in the default
auto
input mode. In
this mode, the receiver automatically detects the input format.
It is also possible to set the input format explicitly.
CMD
means that the connection is to
be used for user command input exclusively.
RTCMv2
,
RTCMv3
and
CMRv2
can be used to
manually select the differential correction format, overriding the auto detection.
RTCMV
is the
LBAS1-proprietary differential correction stream decoded from L-Band.
ASCIIIN
is used for
connections receiving free-formatted ASCII messages, e.g. from an external meteo sensor.
In
auto
mode, the receiver automatically detects the
CMD
,
RTCMv2
,
RTCMv3
,
RTCMV
, or
CMRv2
formats. The other input formats must be specified explicitly.
A connection that is not configured in
CMD
mode or
auto
mode will be blocked for user
commands. There are two ways to re-enable the command input on a blocked connection.
The first way is to reconfigure the connection by entering the command
from another connection. The second way is to send the "escape sequence" consisting of a
succession of ten "S" characters to the blocked connection within a time interval shorter than
5 seconds.
A connection that is configured in
auto
mode will initially accept user commands and dif-
ferential corrections. However, as soon as differential corrections have been detected, the
connection is blocked for user commands until the escape sequence is received.
The
Output
argument is used to select the types of data allowed as output. The receiver
supports outputting different data types on the same connection. The
ASCIIDisplay
is a
textual report of the tracking and PVT status at a fixed rate of 1Hz. It can be used to get a
quick overview of the receiver operation. The
LBandBeami
option is to output the stream
of bytes decoded from an L-Band beam (not available for some proprietary streams).
181
Содержание PolaRx5TR
Страница 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Страница 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Страница 108: ...3 Command Line Reference COM1 gca Ch05 CR R gca Ch05 ChannelAllocation Ch05 G01 auto 0 16000 COM1 108 ...
Страница 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Страница 147: ...3 Command Line Reference PVTMode Static StandAlone SBAS DGPS RTKFloat RTKFixed Cartesian1 COM1 147 ...
Страница 218: ...3 Command Line Reference COM1 esoc COM1 MeasEpoch CR R esoc COM1 MeasEpoch SBFOnce COM1 MeasEpoch COM1 218 ...
Страница 237: ...3 Command Line Reference COM1 237 ...
Страница 251: ...3 Command Line Reference Event type Command etime 1588343730 before 1440 after 1440 Planned Disk DiskEvent COM1 251 ...
Страница 279: ...3 Command Line Reference COM1 279 ...
Страница 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...