10
10
AsteRx-m3 OEM
10
2.5
I/O Connectors
The main connector is the 30-pin connector. That connector must always be connected.
The 60-pin connector provides additional signals (IO enable, serial CTS/RTS lines, GPIOs,
Ethernet, 10-MHz reference input, etc). That connector can be ignored and left
unconnected if these signals are not needed.
Warnings
•
All ground pins must be connected (not applicable to the 60-pin connector if that
connector is not used).
•
Do not drive a non-zero voltage into input pins (pins type
“
I
”
in the tables below)
when the receiver is not powered. In addition, if standby mode is applicable, input
pins must remain in high-Z when the IO_EN signal is not set. See section 2.10 for
details.
•
When pull-up/down resistors are needed, use 10 k
.
•
Unused or reserved pins should be left unconnected unless explicitly mentioned
otherwise.
Conventions
•
Pin Type: I=Input, O=Output, P=Power, Ctrl=Control, Clk=Reference clock
•
LVTTL=3V3 Low Voltage TTL: VI
L
≤ 0.8V, VI
H
≥ 2.0V, VO
L
≤ 0.4V, VO
H
≥ 2.4V.
•
PU: internally pulled up
•
PD: internally pulled down
•
K: keeper input type