SEP LEM012SJ Скачать руководство пользователя страница 2

 

SEP LEM012SJ 2015 V01 

 

1.1 Safety instructions 

 

Information for Your Own Safety 

 

                            This manual does not contain all of the safety measures for operation of the 

LEM012SJ, because special operating conditions, local code requirements or local, 

national or international regulations may necessary to take further measures. It does 
contain information which must be adhered to in the interests of your own personal 
safety and to avoid material damages.   

 
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 

Warning 

Means that failure to observe the instruction can result in death, serious injury or 
considerable material damage. 

 

        Caution 

Means hazard of electric shock and failure to take the necessary safety precautions 

will result in death, serious injury or considerable material damage. 
 
 

 

Qualified personnel 

Commissioning and operation of SEP LEM012SJ described in this manual may only 
be performed by qualified personnel. Qualified personnel in the    sense of the safety 
information contained in this manual are persons who are authorized to commission, 

start up, ground and label devices, systems and circuits according to safety and 
regulatory standards. 

 

Use for the intended purpose 

The SEP LEM012SJ may only be used for the application cases specified in the 

catalog and the user manual and only in connection with devices and components 
recommended and approved by SEP Europe. 
 

Proper handling 

The prerequisites for reliable operation of the product are proper transport, proper 

storage, installation and assembly, as well as proper operation and maintenance. 
When operating electrical equipment, certain parts of this equipment automatically 
carry dangerous voltages. Improper handling can therefore result in serious injury or 

material damage. 
 

 

Use only isolated tools. 

 

Do not connect while circuit is live (hot). 

 

Do not connect the meter to a 3 phase - 400VAC – network. 

 

Place the meter only in dry surroundings. 

 

Do not mount the meter in an explosive area or exposed to dust, mildew and 
insects.   

 

Make sure the used wires are suitable for the maximum current of this meter. 

 

Make sure the AC wires are connected correctly before activating the 
current/voltage to the meter. 

 

Do not touch the meter connecting clamps directly with your bare hands, with 
metal, blank wire or other material as you will have the chance of an electric 
shock and a possible chance for health damage. 

 

Make sure the protection cover is placed after installation. 

 

Installation, maintenance and repair should only be done by a qualified 
personnel. 

 

 

Содержание LEM012SJ

Страница 1: ...0Hz class 1 DIN rail single phase two wire energy meter 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Intrinsic errors 1 6 Description 1 7 Dimensions 1 8 Installation 1 9 Operating 1 10 Troubleshooting 1 11 Technical support User manual ...

Страница 2: ...e The SEP LEM012SJ may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by SEP Europe Proper handling The prerequisites for reliable operation of the product are proper transport proper storage installation and assembly as well as proper operation and maintenance When operating electrical...

Страница 3: ...Any duplication is a violation of the law and subject to criminal and civil penalties All rights reserved particularly in the event of a patent award or utility model registration Registered trademarks SEP EUROPE is registered trademark of Schotman Elektro BV 1 2 Foreword Thank you for purchasing the SEP LEM012SJ DIN rail single phase two wire energy meter The LEM012SJ energy meter is an advanced ...

Страница 4: ... Reference current Iref 20 A Maximum current Imax 100 A Operational current range 1 0A 100A Over current withstand 3000A for 0 01s Operational frequency range 50Hz 10 Internal power consumption 2W 10VA Test output flash rate PULSE LED 500 pulses per kWh 2 0Wh imp Pulse output rate pins 20 21 500 pulses per kWh 2 0Wh imp Pulse supply current Ui max 27V Ii max 27mA Power supply indicator POWER LED M...

Страница 5: ...etarding polycarbonate Protection cover Fiber glass reinforced inflaming retarding polycarbonate E D D E 2 0 S O 6 3 1 4 N L 2 1 U i m a x 2 7 V li m a x 2 7 m A Single phase 100A kWh meter R L 2 0 W h im p R A 2 0 W h im p t i 8 0 m s S O R DMMeteri ng ADM 2 D V1 0 EN 50470 3 POWE R PU LSE R D M Me t eri ng kW h RA 2 0 W h imp R L 2 0 W h im p E N 5 0 4 7 0 3 B 230V 1 20 100 A 50Hz A B B C B A C ...

Страница 6: ...t all power supplying the energy meter and the equipment to which it is installed before working on it Always use a properly rated voltage sensing device to confirm that power is off WARNING Installation should be performed by qualified personnel familiar with applicable codes and regulations Use isolated tools to install the meter Fuse or thermal cut off or single pole circuit breaker can t be fi...

Страница 7: ...cifications of the building electrical design and all local regulations This meter can be installed indoor directly or in a meter box which is waterproof outdoor in compliance with the local codes and regulations The meter has to be installed in a good ventilated and dry place The meter has to be installed in a protection box in dangerous or dusty environment The meter can be installed and used af...

Страница 8: ...there is For this LED the flash rate is 500 impulses per kWh 2 0Wh imp Reading the meter LEM012SJ is equipped with a white backlight LCD display During the normal working hours the backlight will be on all the time LCD display will show the following energy data and indication message a Current total energy When the meter is in normal working it will display only 7 1 energy data with The unit is k...

Страница 9: ...h an pulse output which is fully separated from the inside circuit The generated pulses are in proportion to the measured energy for remote reading purposes and accuracy testing The pulse output is a polarity dependant passive transistor output requiring an external voltage source for correct operation For this external voltage source the voltage Ui should is 5 27V DC and the maximum input current...

Страница 10: ... performed by qualified personnel familiar with applicable codes and regulations Use insulated tools to maintain or repair the meter Make sure the protection cover is in place after maintenance or repair Case is sealed failure to observe this instruction can result in damage for meter Problem Check Solution No light for the Power supply indicator Is AC power supply connected to the meter Is the 1 ...

Страница 11: ... a fault in the inside circuit Check that the power supply indicator is burning If the operating power is too low the spacing interval of running will be prolonged so that people is under the delusion that register can t run Contact a qualified technician When necessary replace the meter LCD backlight can t lit Is there a power supply inside the meter Maybe there is a fault in the inside circuit C...

Страница 12: ...ibutor Email mail sep europe nl www sep europe nl Maybe there is a fault in the inside circuit Contact a qualified technician When necessary replace the meter Pulse output rate wrong Maybe there is a fault in the inside circuit Contact a qualified technician When necessary replace the meter S E P Europe Weverstraat 4 9403 VJ Assen Netherlands Tel 31 0 88 54 60735 ...