Installation Guide for the SolaStat™-Plus-ET 

Version 1.2 – July 2011 

 

 

 

 

 

Page 7 

B

EFORE 

I

NSTALLATION

,

 

C

ONTINUED

 

  

Assemble the 
tools you will 
need 

You will need the following tools to install the SolaStat

TM

-Plus-ET: 

  Philips1 screwdriver for lid screws 

  Pozi2 screwdriver for mounting screws 

Note: These tools are needed to mount the SolaStat

TM

- Plus-ET only, and 

other tools may be needed for the remainder of the installation including the 
sensors. 

 

 

READ THESE SAFETY PRECAUTIONS and LIMIT OF LIABILITY BEFORE INSTALLATION 

The following pages contain instructions for qualified personnel only and involve 
potentially hazardous adjustments and high voltage mains wiring information. 

  

General 
Safety 
Precautions 

1.  This installation guide is for the installation of SolaStat

TM

-Plus-ET solar 

hot water controllers only and is not an installation guide for any other 
part. 

2.  The complete installation should be checked at least annually for damage 

or malfunction. 

3.  All servicing to be carried out by an authorised service agent only. 

4. 

All aspects of the installation must comply with local electrical and 
plumbing regulations (and any special solar hot water regulations).

 

  

Installation 
Precautions 

1.  Must be installed away from water sources such as rain, leaking pipes, or 

wet floors and must not be installed in damp areas like bathrooms. 

2.  Must be installed away from direct sunlight, flammable liquids or radiant 

heat sources. 

3.  Power leads must be facing directly down, not sideways or upwards. 

4.  Must be in a safe environment for users to inspect display panel. 

5.  Failure to mount sensors correctly can lead to a poorly controlled solar 

water system with safety issues such as: 

  overheating and over pressure damage to the plumbing and the tank 

  freezing damage to the solar collector. 

6. 

Alteration of installer level program values outside those recommended 
values recommended by SolaStat

TM

 / Senztek

TM

 and other parts suppliers 

(especially hot water tank manufacturer’s maximum recommended 
temperature) can lead to dangerous conditions and/ or damage to parts 
of the solar hot water system.

 

 

Continued on next page 

Содержание SolaStat-Plus-ET

Страница 1: ...SolaStatTM Plus ET Installation Guide FOR QUALIFIED PERSONNEL ONLY Version1 2 July 2011...

Страница 2: ...StatTM Plus ET 9 Mounting the Sensors 10 Installation and Wiring 12 Powering Up 13 Installer Programming 14 Sensor Maintenance 21 SolaStatTM Plus ET Plumbing Issues 24 Trouble Shooting Guide 27 SolaSt...

Страница 3: ...ce installation Power light indicates that the unit has power When the PUMP and FROST lights are on the pump is circulating water to stop the collector from freezing When the t appears at the left sid...

Страница 4: ...rection of some problems It will also keep you informed of the measurement and the decisions it is making P Pr ri in nc ci ip pl le e o of f O Op pe er ra at ti io on n There are three key things to r...

Страница 5: ...mp and has been effective as a backup in exceptional conditions This feature can help prevent the pump running for hours in a locked up state increasing the installation reliability This will not affe...

Страница 6: ...erature TANK Temperature INLET Temperature To read each reading follow the steps below Continued on next page 1 When switching on the power the TANK light will be on and the tank temperature will be d...

Страница 7: ...Plus ET Version 1 2 July 2011 Page 5 USING YOUR SOLASTAT TM PLUS ET CONTINUED 5 The ROOF light is on and the Roof temperature is displayed in this case 70 C 6 Press to proceed and the display will ret...

Страница 8: ...FORE INSTALLATION Assemble the components you will need The SolaStatTM Plus ET solar hot water controller includes the following components Roof sensor TANK sensor INLET sensor SolaStatTM Plus ET Cont...

Страница 9: ...3 All servicing to be carried out by an authorised service agent only 4 All aspects of the installation must comply with local electrical and plumbing regulations and any special solar hot water regul...

Страница 10: ...s 3 It is recommended that sensor leads be kept 300mm away from mains and comms cables 4 Do not use mains power extension cords unless approved by the manufacturer Water resistant plugs and sockets sh...

Страница 11: ...pen the enclosure during a standard installation For a standard installation follow these steps 1 Allow for the enclosure dropping 5mm from screw centres once mounted keyhole mounting 2 Place drill gu...

Страница 12: ...used 2 The 2m Tank Sensor Labelled TANK SENSOR connects to the top of the hot water tank is best fitted into a metal immersion pocket in the upper region of the hot water tank Senztek also offer mount...

Страница 13: ...orrect place 5 Failure to properly mount the Tank and Inlet Sensor as prescribed in the method above can result in i The system not operating at greatest efficiency ii Inaccurate tank and inlet temper...

Страница 14: ...sed as a general guide and not all the required components are shown Each installation needs to be customised to suit its situation Always use best plumbing and electrical practices and comply with an...

Страница 15: ...of the TANK temperature in C The PWR light and the TANK light should be on Right lights will be on indicating how the system is operating Testing The collector pump operation can be tested by pressin...

Страница 16: ...n Winter 6 Energy Transfer On in Winter 7 Frost 8 Topout These are explained in more detail below Heating Mode Heating Mode triggers heating of the tank and involves two values Pump Off the ROOF senso...

Страница 17: ...Mode is activated Repeat this to go back to Summer Mode Example Energy Transfer Off in Summer 60 C Energy Transfer On in Summer 70 C When the tank temperature has reached to 70 C the energy transfer...

Страница 18: ...is the value stored as the maximum allowable hot water tank temperature If the tank reaches to the topout temperature t will be displayed at the left side of the screen for ROOF TANK INLET reading Th...

Страница 19: ...Programming Table for Adjustable Values Adjustable Values Light Indication Typical Factory Values Range Disabled Installation Values Pump Off PUMP Flashing 6 C 1 C 20 C N A ________ C Pump On PUMP St...

Страница 20: ...s Continued on next page 1 Press the key 2 All the display lights will come on for a few seconds Wait for the pump counter to display 3 After all lights have finished flashing only then press 4 Then p...

Страница 21: ...alue entry Note 2 After each key press you have a minute to press another key before the unit times out See next page for an example Continued on next page 1 Use and to increase or decrease values to...

Страница 22: ...o increase or to decrease Pump On value to 12 Step 3 Press Press to increase or to decrease Energy Transfer Off in Summer value to 60 Step 4 Press Press to increase or to decrease Energy Transfer On i...

Страница 23: ...rmly attach wires to each other by either soldering heatshrink over each joint or by quality screw terminals Joints must be kept dry It is recommended that sensor leads be kept 300mm away from mains a...

Страница 24: ...on each corner of the lid of the enclosure This will require a fine tipped tool such as a screw driver Be careful not to damage the lid Always press the tool away from you to avoid injury if you slip...

Страница 25: ...See section of this manual Sensor Resistances The table below has the correct resistance values of the sensor at different temperatures The sensor must be removed from the SolaStatTM Plus ET to measu...

Страница 26: ...ts including the pump must be rated for the elevated temperatures found in solar hot water systems Non Return Valve System Hot water rises and cold water falls If the solar collector is colder than th...

Страница 27: ...in a pump is more likely to occur as the temperature of the water rises and or the pressure of the water decreases Bubbles form when the water is sucked into the pumps impellor and collapse again as...

Страница 28: ...has enough head pressure is best as this will create the lowest pressure difference in the pump 3 Mount the pump as low as possible to achieve highest water pressure out of the tank feeding into the p...

Страница 29: ...noise like stones passing through it then it is cavitating See Plumbing Issues 3 Check programming is correct 4 Air Relief Valves not installed functioning Pump runs at night FROST light is ON a Frost...

Страница 30: ...rost Protection 1 10 C with 2 C hysteresis or OFF Topout 1 120 C with 2 C hysteresis or OFF EMC and Safety Compliances Emissions EN 55022 A CTick Immunity EN 50082 1 Safety Compliance EN 60950 CTick G...

Отзывы: