Installation Guide for the SolaStat™-Plus-ET
Version 1.2 – July 2011
Page 17
I
NSTALLER
P
ROGRAMMING
,
C
ONTINUED
Adjustable
Values
Worksheet
The unit will need to be programmed where the adjustable values from the
factory are inappropriate for the installation. Once new values are stored,
they are permanently written into memory and will be retained when power is
removed.
Immediately after programming (at installation or after any change in
program adjustable values) please fill out the Programming Table for
Adjustable Values below.
Programming Table for Adjustable Values
Adjustable Values
Light Indication
Typical
(Factory
Values)
Range
Disabled
Installation
Values
Pump Off
PUMP Flashing
6ºC
1ºC
20ºC
N/A ________ºC
Pump On
PUMP Steady
12ºC
2ºC
21ºC
N/A ________ºC
Energy Transfer
Off in Summer
TRAN Flashing Slow
60ºC
1ºC
70ºC
<1ºC = OFF
________ºC
Energy Transfer
On in Summer
TRAN Flashing Fast
70ºC
2ºC
90ºC
N/A ________ºC
Energy Transfer
Off in Winter
TRAN Flashing Slow +
WINTER Steady
40ºC
1ºC
70ºC
<1ºC = OFF
________ºC
Energy Transfer
On in Winter
TRAN Flashing Fast +
WINTER Steady
55ºC
2ºC
90ºC
N/A ________ºC
Frost FROST
Steady
4ºC
1ºC
10ºC
>10ºC = OFF
________ºC
Topout
PUMP + TRAN +
FROST
Steady
80ºC
1ºC
120ºC
<1ºC = OFF
________ºC
Continued on next page