Error Codes
Error
code
E0
E1
E3
E4
E5
EC
F0
F1
F2
F3
F4
F5
P0
P1
P2
P3
P4
P6
Indoor unit EEPROM parameter error
Indoor / outdoor units communication error
Indoor fan speed has been out of control
Indoor room temperature sensor T1 open circuit or short circuit
Evaporator coil temperature sensor T2 open circuit or short circuit
Refrigerant leakage detection
Overload current protection
Outdoor ambient temperature sensor T4 open circuit or short circuit
Condenser coil temperature sensor T3 open circuit or short circuit
Compressor discharge temperature sensor TP open circuit or short circuit
Outdoor unit EEPROM parameter error
Outdoor fan speed has been out of control
IPM malfunction or IGBT over-strong current protection
Over voltage or over low voltage protection
High temperature protection of IPM module
Outdoor ambient temperature too low.
Inverter compressor drive error
Low pressure protection
(Only for Multi-Zone Units)
Note:
For additional information on how to further diagnose the error codes on the unit, you can go to our website:
https://support.senville.com
Operation
lamp
Timer
lamp
☆
1 time
X
☆
2 times
X
☆
4 times
X
☆
5 times
X
☆
6 times
X
☆
7 times
X
☆
8 times
X
☆
1 time
O
☆
2 times
O
☆
3 times
O
☆
4 times
O
☆
5 times
O
☆
6 times
O
☆
7 times
O
☆
1 times
☆
☆
2 times
☆
☆
3 times
☆
☆
4 times
☆
☆
5 times
☆
☆
6 times
☆
☆
7 times
☆
☆
8 times
☆
EE
Water-level alarm malfunction
F6
Indoor coil outlet pipe sensor
(Located on outdoor unit low pressure valve)
P5
Indoor units mode conflict
P7
Outdoor IPM temperature sensor error