background image

L4AS

P. 1 / 3

EM-1991 Rev.6

BEFORE USE ....

Thank you for choosing M-System.  Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.

■ 

PACKAGE INCLUDES:

Signal conditioner ................................................... (1)

■ 

MODEL NO.

Check that model No. described on specification label is
exactly what you ordered.

■ 

INSTRUCTION MANUAL

This manual describes necessary points of caution when you
use this product, installation, connection and basic mainte-
nance procedures.

COMPONENT IDENTIFICATION

■ 

FRONT PANEL CONFIGURATION

INSTRUCTION  MANUAL

MODEL

L4AS

QUAD DC ALARM

INSTALLATION

■ 

DIN RAIL MOUNTING

Set the unit so that its DIN rail adaptor is at the bottom.
Position the upper hook at the rear side of the unit on the DIN
rail and push in the lower.  When removing the unit, push
down the DIN rail adaptor utilizing a screwdriver (–) and
pull.

■ 

WALL MOUNTING  mm (inch)

MODEL

 L4AS

50

100

%

0

2

1

3

4

50

100

%

0

50

100

%

0

50

100

%

0

Specification Label

Connection Diagram

Body

1

2

3

4

Monitor LED

Setpoint Adj.

1

2

3

4

Monitor LED

Setpoint Adj.

SCREWDRIVER ADJUSTMENTS

DIAL ADJUSTMENTS

DIN Rail

35mm wide

Spring Loaded

DIN Rail Adaptor

2–M5

60 (2.36)

75 (2.95) MIN.

60 (2.36)

60 (2.36)

M5 SCREWS

2–M4

60 (2.36)

75 (2.95) MIN.

60 (2.36)

50 (1.97)

M4 SCREWS

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Содержание M-SYSTEM L4AS

Страница 1: ... AC Operational voltage range 170 264 V AC 47 66 Hz DC Power R 24 V DC Operational voltage range 24 V 10 ripple 10 p p max P 110 V DC Operational voltage range 85 150 V ripple 10 p p max GENERAL SPECIFICATIONS Construction Stand alone terminal access at the front Connection M3 5 screw terminals Housing material Flame resistant resin black Isolation Input to output to power Setpoint adjustments Sin...

Страница 2: ... 14 16 turn ON INSTALLATION Power Consumption AC Power input Approx 4 5 VA DC Power input Approx 2 W 80 mA at 24 V Operating temperature 5 to 55 C 23 to 131 F Operating humidity 30 to 90 RH non condensing Mounting Surface or DIN rail Weight 350 g 0 77 lbs PERFORMANCE in percentage of span Setpoint accuracy 0 3 Temp coefficient 0 05 C 0 03 F Response time 0 5 sec 0 100 at 90 setpoint Line voltage e...

Страница 3: ...JUSTMENTS ع DIAL ADJUSTMENTS EXTERNAL DIMENSIONS TERMINAL ASSIGNMENTS unit mm inch 112 4 41 3 3 13 35 4 1 39 DIN RAIL 35mm wide 14 55 8 31 16 M3 5 SCREW 75 2 95 80 3 15 TERMINAL COVER 2 5 8 23 dia or 2 4 8 18 dia MTG HOLE 8 31 deep 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 Dial adj Rugghölzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com www sentronic com Prod...

Страница 4: ...it DC Powered LOAD Inductive Load Coil Diode Varistor or CR Circuit Relay Protection AC Powered Comparator Ry 13 12 11 Comparator Ry 16 15 14 Comparator Ry No 1 SET No 2 SET No 3 SET No 4 SET ALARM OUTPUT 2 ALARM OUTPUT 3 ALARM OUTPUT 4 ع Specifications are subject to change without notice Rugghölzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com www sentron...

Страница 5: ...RM INSTALLATION DIN RAIL MOUNTING Set the unit so that its DIN rail adaptor is at the bottom Position the upper hook at the rear side of the unit on the DIN rail and push in the lower When removing the unit push down the DIN rail adaptor utilizing a screwdriver and pull WALL MOUNTING mm inch MODEL L4AS 50 100 0 2 1 3 4 50 100 0 50 100 0 50 100 0 Specification Label Connection Diagram Body 1 2 3 4 ...

Страница 6: ...5mm wide 14 55 8 31 16 M3 5 SCREW 75 2 95 80 3 15 TERMINAL COVER 2 5 8 23 dia or 2 4 8 18 dia MTG HOLE 8 31 deep 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 Dial adj U V 9 10 INPUT POWER 1 2 5 4 3 8 7 6 ALARM OUTPUT 1 13 12 11 16 15 14 ALARM OUTPUT 2 ALARM OUTPUT 3 ALARM OUTPUT 4 Rugghölzli 2 CH 5453 Busslingen Tel 41 0 56 222 38 18 Fax 41 0 56 222 10 12 mailbox sentronic com www sentronic com Produkte...

Страница 7: ... input and output close to noise sources relay drive cable high frequency line etc Do not bind these cables together with those in which noises are present Do not install them in the same duct AND The unit is designed to function as soon as power is supplied however a warm up for 10 minutes is required for satisfying complete performance described in the data sheet MAINTENANCE Regular calibration ...