3. Connect the wires for the humidity sensor to the terminals labelled “
+ S -
”
in terminal strip
2
.
c. Connect the green wire to terminal “
+
”.
d. Connect the orange wire to terminal “
S
”.
e. Connect the red wire to terminal “
-
”.
5.10. Connecting the foil sensor (optional)
1. Guide the wires for the sensor through the cable bushing
5
into the low-
voltage connection area
1
.
2. Connect the wires for the sensor to the terminals labelled “
FF
” in terminal
strip
2
.
5.11. Status output
Any electrical device can be connected to the status output terminal which is
suitable for 24 V DC voltage and draws a current no greater than 200 mA.
Make sure the polarity is correct when connecting a device. When LEDs are
used, a suitable series resistor must be used.
5.12. Finishing installation
1. Connect the earth conductor for the power supply cable and all devices to
the earth rail
h
.
2. Place the cover of the housing on the upper edge of the junction box.
3. Push the clip locks inwards lightly, and turn the cover of the housing down-
wards until it engages audibly.