background image

WORLD OF WELLNESS

2.  Connection

All the individual modules are connected via data cables; here there is a difference between 

the 4-pin data cables (RJ10) and the 6-pin data cables (RJ12). The RJ12 cables are used 

to connect the individual power supply units and the touch operating unit to one another 

and the RJ10 cables are used for the interior operating units. The following wave.com4 

modules are available and can be used with the touch operating unit:

 

wave.com4 sauna

 

wave.com4 infra

 

wave.com4 sound&light

Important: 

If just the wave.com4 sauna and wave.com4 sound&light are being used, 

the 

WC4-SL-EXT

 extension cable set must be ordered. 

Once all the components have been connected, the power supply units need to be pre

-

pared for use with the touch unit.

wave.com4 Touch

wave.com4 Infra

RJ12

RJ12

RJ12

wave.com4

sound&light

wave.com4

Sauna

   RJ12

Innenbedienteil

Sauna

RJ10

Innenbedienteil

sound&light

RJ10

Connection example for complete con-

figuration with 2 interior operating units:

Connection example without wave.com4 infra:

JPBM

wave.com4 sauna

Attach the 

JPBM

 jumper wire to the sauna power supply unit. This jumper wire is included 

in the delivery scope of the touch operating unit.

WC4-SL-EXT

RJ10 

RJ12

wave.com4 Touch

wave.com4

sound&light

wave.com4

Sauna

RJ12

RJ12

Содержание 1-015-611

Страница 1: ...rhandbuch zur Hand 1 Technische Daten Betriebsspannung 12 24 VDC Versorgung ber Datenleitung Leistungsaufnahme max 5 6 W Standby max 1 W Display 3 5 TFT 320 x 240 px Lautsprecher 2 x 5 W 8 Ohm Umgebun...

Страница 2: ...ird nur wave com4 Sauna und wave com4 sound light verwendet muss das Erweiterungskabelset WC4 SL EXT bestellt werden Nachdem alle Komponenten miteinander verbunden wurden m ssen die Leistungsteile f r...

Страница 3: ...e angeschlossen m ssen die BUS Adressen der Bedienteile an gepasst werden Die Vorgehenesweise daf r befindet sich in der jeweiligen Anleitung Das Innenbedienteil f r sound light es k nnen 2 Innenbedie...

Страница 4: ...edienteil verwendet muss als Audioquelle TC4 eingestellt werden Die Lautsprecher m ssen in diesem Fall an der Touch Bedienteil R ckseite angeschlossen werden Softwareupdate Laden Sie die aktuelle Soft...

Страница 5: ...Jumper JPSL am sound light Leistungsteil berpr fen Netzanschluss sound light Leistungsteil berpr fen Datenkabel berpr fen Touch Bedienteil spielt keine Musik ab Einstellung Audioquelle im Technikermen...

Страница 6: ...WORLD OF WELLNESS NOTIZEN APPUNTI NOTES NOTE NOTITIES...

Страница 7: ...user manual 1 Technical data Operating voltage 12 24 V DC supply via data cable Power consumption max 5 6 W standby max 1 W Display 3 5 TFT 320 x 240 px Loudspeakers 2 x 5 W 8 Ohm Ambient conditions 0...

Страница 8: ...m4 sauna and wave com4 sound light are being used the WC4 SL EXT extension cable set must be ordered Once all the components have been connected the power supply units need to be pre pared for use wit...

Страница 9: ...rating units are connected to one function sauna or infra the BUS addresses of the units need to be adapted The procedure for this can be found in the respective manual The interior operating unit for...

Страница 10: ...g unit is being used TC4 must be set as the audio source In this case the loudspeakers must be connected to the back of the touch operating unit Software update Download the current software from our...

Страница 11: ...our light menu item Check the JPSL jumper wire on the sound light power supply unit Check the sound light power supply unit Check the data cable Touch operating unit does not play music Check the audi...

Страница 12: ...sentiotec GmbH world of wellness Oberregauer Stra e 48 4844 Regau Austria Tel 43 0 7672 277 20 800 Fax 43 0 7672 277 20 801 E mail info sentiotec com www sentiotec com...

Отзывы: