Sentier Vetcorder Pro Скачать руководство пользователя страница 1

 

    

  

  

  

Vetcorder Pro 

 

 

 

 

 

 

1.

 

The  Basics ................................................................................................ 1

 

2.

 

Introduction  ............................................................................................ 2

 

3.

 

Getting  Started ........................................................................................ 7

 

4.

 

Using  Vetcorder ....................................................................................... 8

 

6.

 

Review ................................................................................................... 22

 

7.

 

Maintenance  ......................................................................................... 24

 

9.

 

Accessories ............................................................................................ 27

 

10.

 

Specifications  ........................................................................................ 28

 

11.

 

Electromagnetic  Compatibility .............................................................. 31

 

 

 

EVERY PATIENT EVERY TIME 

User’s Manual 

1.

 

The Basics 

This manual contains the instructions necessary to operate the 

product safely and in accordance with its function and intended 

use. Observance of this manual is a prerequisite for proper 

product performance and correct operation and ensures user and 

operator safety. 

  

1.1

 

Safety 

 Warnings and Cautionary Advice

 

 

Before using the device, please ensure that you have read 

this manual thoroughly and fully understand corresponding 

precautions and risks.  

 

The data and results displayed on the device are for 

reference only and cannot be directly used for diagnostic 

interpretation or treatment. 

 

Do not use this device with a defibrillator. 

 

Do not use this device during MRI examination. 

 

Do not use the device in a combustible environment (i.e., 

oxygen-enriched environment). 

 

Never submerge the device in water or other liquids. Do not 

clean the device with acetone or other volatile solutions. 

 

Do not drop this device or subject it to strong impact. 

 

Do not place this device in pressure vessels or gas 

sterilization device. 

 

Do not dismantle the device, as this could cause damage or 

malfunctions or impede the operation of the device. 

 

Do not allow the electrodes to contact other conductive parts 

(including the ground). 

 

Do not store the device in the following locations: locations 

in which the device is exposed to direct sunlight, high 

temperatures or levels of moisture, or heavy contamination; 

locations near to sources of water or fire; or locations that 

are subject to strong electromagnetic influences.

 

Содержание Vetcorder Pro

Страница 1: ...1 The Basics 1 2 Introduction 2 3 Getting Started 7 4 Using Vetcorder 8 6 Review 22 7 Maintenance 24 9 Accessories 27 10 Specifications 28 11 Electromagnetic Compatibility 31 EVERY PATIENT EVERY TIME...

Страница 2: ...ot use this device during MRI examination Do not use the device in a combustible environment i e oxygen enriched environment Never submerge the device in water or other liquids Do not clean the device...

Страница 3: ...ysiological parameters including ECG pulse oxygen saturation SpO2 perfusion index PI pulse rate and internal temperature It is not intended for use on humans 2 2 About Vetcorder 1 Touch Screen Use the...

Страница 4: ...or Calendar Screen or return to Home Screen 4 Temperature Probe Connector Port 5 ECG Connector Port 6 SpO2 Connector Port 7 Speaker 8 Serial Number 2 3 Main Screen The Main Screen is shown as below Sw...

Страница 5: ...e Main Screen 1 Current time 2 Current date You can change the current time and date by going into the Settings menu Please refer to Section 5 1 for details 3 This arrow indicates Users to press the H...

Страница 6: ...will be provided after the measurement is finished An example is shown as below 1 Measured parameters and readings 2 Trash replay and back buttons Select to move recording to trash Select button to r...

Страница 7: ...ical products should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice IP22 Against ingress of solid foreig...

Страница 8: ...n be notified via email of any software updates etc When disposing of the packaging material be sure to observe waste control regulations and keep it out of the reach of children and animals The equip...

Страница 9: ...e the Bluetooth is on and when that circle is on the left the Bluetooth is off You can exit this menu by using the X in the upper right corner or by using the home button to return to the starting scr...

Страница 10: ...ication site Do not use this device during defibrillation Interference from a non grounded instrument near the animal patient and electro surgery interference can cause problems with the waveform The...

Страница 11: ...not use the Pulse Oximeter on the same paw leg when using a blood pressure cuff or monitor Do not use the Pulse Oximeter outside the specified operating and storage temperature ranges DO NOT USE this...

Страница 12: ...t s health status it is recommended to take Daily Check measurements at a regular interval To ensure that you never forget to take a daily Check measurement you can set a daily reminder When the daily...

Страница 13: ...art rate and SpO2 To view the trend select one record and then tap the button For details please refer to Section 6 1 4 3 ECG Recorder About ECG Recorder Warnings and Cautionary Advice Before using th...

Страница 14: ...e instructions to connect the ECG cable and place the ECG electrodes Keep Pet calm 5 The display will then show your ECG waveform The device will monitor the animal s ECG continuously however no data...

Страница 15: ...o mobile devices For instructions on how download and or share an ECG or Daily Check recording please visit https www sentierconnect com 4 5 Reminder Up to 6 reminder events can be set by user You can...

Страница 16: ...e and buttons to scroll through menu Tap the third row set the time when the reminder is triggered then tap Tap to save this reminder To edit or delete a reminder in the Reminder menu choose the remin...

Страница 17: ...se rate PR and perfusion index PI will also be measured and displayed The Perfusion Index is a relative assessment of the pulse strength at the monitoring site Measuring 1 Connect the external SpO2 se...

Страница 18: ...for use in that area Before each use check that the probe is intact If it is damaged do not use please contact your distributor or Sentier Holding the device in your hand or carrying it in a pocket ca...

Страница 19: ...1 The Monitor Vitals feature on the Vetcorder allows for continuous monitoring of ECG SpO2 Temperature and Heart Rate An audible beep can be heard whenever a heart rate is detected by the ECG Up to 1...

Страница 20: ...and Heart Rate 5 Opening Settings Menu To open the Settings menu 1 Press the Home button to enter the Main Screen 2 Tap the Settings icon to open the menu as below In the Settings menu you can Tap and...

Страница 21: ...choose General Tap the ECG bandwidth to change between Normal and Wide 5 4 Erasing Data 1 In the Setting menu choose General 2 Arrow down to Erase All Data and then Yes All measurements saved in the d...

Страница 22: ...ing information 4 Tap to return the Pet Management menu To edit the information of a Pet 1 In the Settings menu choose Pet Management 2 Choose the Pet that you want to edit 3 Tap the information that...

Страница 23: ...he mobile app select your Vetcorder to pair then navigate to your recording type to select and download recordings Note Full instructions available at www sentierconnect com 6 Review To open the Data...

Страница 24: ...Reviewing ECG Recorder To review ECG Recorder records in the Data Review menu select The operations you can perform are almost the same with Daily Check however there is no trending graph 6 3 Reviewin...

Страница 25: ...le Lithium ion battery The battery charges automatically when the monitor is connected to AC power or devices that can output electronic power through USB connector such as personal computer and mobil...

Страница 26: ...during charging Use charging adapter provided by manufacturer or USB charging devices that comply with the standard of IEC 60950 8 Clean the device weekly carefully swabbing the device surface with a...

Страница 27: ...too much 2 Leg or body may be moving 1 Reattach electrode s hold the device stably and gently 2 Try to keep animal perfectly still and test again The app cannot find the device The Bluetooth may not...

Страница 28: ...all Animal SPO2 Lingual Clip 7100 1616 Small Animal ECG Cable 2 Ft Long 7100 1604 Small Animal ECG Clips Silver 2pcs 7100 1614 Small Animal ECG Clips Blue 2pcs 7100 1605 USB Charging Cable Micro D 710...

Страница 29: ...Display Vetcorder 2 7 touch screen HD Connector Micro D connector Wireless connectivity Built in Bluetooth dual mode support 4 0 BLE Power Supply Charge adapter input AC100 240V 50 60Hz Charge adapter...

Страница 30: ...e measured with a CO oximeter Pulse oximeter measurement are statistically distributed and about two thirds of the measurements are expected to come within the specified accuracy range compared to CO...

Страница 31: ...d models launched subsequently iPad 3 and models launched subsequently Android Capability Mobile phone or pad with Bluetooth 2 1 or above Functionality Data export data review waveform replay trend re...

Страница 32: ...and mobile communication equipment may affect the performance of this device Other devices that have RF transmitter or source may affect this device e g cell phones PDAs and PCs with wireless functio...

Страница 33: ...e IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Voltage dips short Interruptions and Voltage variations on power supply input lines IEC 61000 4 11...

Страница 34: ...fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked wi...

Страница 35: ...tance according to frequency of the transmitter m 150 kHz 80 MHz 80 MHz 800 MHz 800 MHz 2 5 GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 20 1 20 2 30 10 3 80 3 80 7 30 100 12 00 12 00 23 00 For tran...

Страница 36: ...r whatsoever without the written permission of Sentier is strictly forbidden Contents of this manual are subject to changes without prior notice All information contained in this manual is believed to...