Doc 6001051, Rev C
3 - Wiring
SYSTEM POWER
Connect 2 conductor cable (for wire size, see Table 1
below) from TB4 at the Mini-Key unit to the 12VAC, 20
VA transformer supplied by Sentex (or 13.5 VDC power
supply that you provide).
Do not connect the power to the system until all
connections have been made to the system.
Please Note:
If you are using a DC power supply, the
Mini-Key system will not trickle charge a battery, so the
DC power must be supplied by an uninterruptible power
supply (UPS).
1051F7
TB4
12V AC/DC
PWR IN
2 Conductor Cable
(See Table for Wire Size and Distance)
Figure 5: Power Connections
DISTANCE
AC POWER WIRE SIZE
DC POWER WIRE SIZE
30' and under
18 AWG
18 AWG
30'-75'
18 AWG
18 AWG
75'-150'
14 AWG
18 AWG
150'-250'
12 AWG
16 AWG
250'-500'
10 AWG
12 AWG
Table 1: Power Wire Distance
DOOR/GATE CONTROL
Connect the 2 conductor cable from your door strike and door strike power supply or from your gate operator to the
relay contacts in area TB1 as follows:
Door Strikes
TB1
COM1
COM2
NO1
NO2
2 / 18-22 AWG
1051F12
(DC)
+
(DC)
+
AC (24v max.) or DC
POWER SOURCE
DOOR STRIKE
(DC)
(DC)
Relay 1: Connect as Shown.
Relay 2: Connect wires
to COM2 and NO2
DC Powered Strikes
AC Powered Strikes
:
:
Use a 1N4001 Diode
or equiv.
Use a Siemens
S10K30 MOV
(Metal Oxide Varistor)
or equiv.
Figure 6: Normally Locked Strikes