![Sentex Sentex MINI-KEY Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/sentex/sentex-mini-key/sentex-mini-key_installation-instructions-manual_1244523013.webp)
Doc 6001050, Rev C
Page 4 of 5
SECTION 2
INITIAL SYSTEM SETUP
A. RELAY ACTIVATION TIMES
Set the amount of time the gate/relay will remain activated. The default setting is 10 seconds and the valid time
range for activation is 2-255 seconds.
Format:
1 + no. of s #
Main Relay
2 + no. of s #
Auxiliary Relay
Note
:
If this relay activates a gate operator with a momentary contact closure, set the relay activation
time for a short period (for example, 2 seconds). A longer activation time might cause the gate to
repeatedly open and close until the activation period has expired.
B. NUMBER OF DIGITS IN ENTRY CODES
If you decide to change the number of digits in the entry codes
after
the initial programming, you will need to
delete all of the entry codes before changing the code length (see section 7.C). Once the change in code length
has been made, the old codes will no longer be valid and cannot be erased
.
Default setting is for 4-digit entry
codes and the valid range is 4 or 5 digits
Format
8 + number of digits (1 digit) + #
Example
8 + 5 + # (sets the number of digits in entry codes to 5)
.
C. STRIKES-AND-OUT
Set how many incorrect entry codes may be entered within a 3 minute period before the system deactivates for a
period of 3 minutes. The "strike count" will be cleared when either a valid entry code is entered or if the keypad
has not had any input for 60 seconds since the last keystroke. When the "strike count" has been reached, all
keypad input will be ignored, including access to the programming mode.
Format
3 + number of incorrect codes (up to 2 digits) + #
Example
3 + 3 + # (sets strikes-and-out to 3).
Notes
Valid range is 0 to 10.
•
Default setting is 5.
•
To disable the strikes-and-out enter zero (0).
D. CHANGE THE PASSWORD
Ensure that the password required to enter the programming mode is known only by authorized personnel. Make
sure to write down the new password so you can re-enter programming at a later date.
Format
9 + password (6 digits) + #
Example
9 + #
(If the unit responds with two short beeps, the number that you entered was accepted)
E. VERIFY THE PASSWORD
Verify the password entry to ensure proper setting. If the password entered is correct, two short beeps will be
emitted from the system. If it is the incorrect code, the system will emit one long beep.
If the unit responds with an error tone,
do not exit programming.
The number that you entered does not match
the password. Repeat steps D and E for proper password setting
Format
4 + password (6 digits) + #
Содержание Sentex MINI-KEY
Страница 15: ......