www.sentera.eu
MIW-MTY-7-15-AT-EN-000 - 19 / 09 / 2019
6 - 8
Fig. 1 Wiring and connections
Minimum speed
adjustment trimmer
(factory pre-set to
100 VAC)
Power supply
(120 VAC ±10 % / 60 Hz)
Unregulated output voltage
120 VAC / max. 1,5 A
Unregulated output, neutral
Regulated output to motor
Regulated output to motor, neutral
4.
Mount the internal enclosure into the wall according to the mounting dimensions
shown in
Fig. 2
. “
Mounting dimensions - inset mounting”.
Fig. 2 Mounting dimensions - inset mounting
82
82
26
33
50x50
62
50
62
60
62
50
62
60
5.
Using a flat screwdriver, adjust the Vmin trimmer (the factory setting is 100 VAC).
6.
Mount back the cover and secure it with the nut.
7.
Put back the knob and turn it to off position.
8.
Turn on the power supply.
For surface mounting
1.
Remove the knob by turning it to the right until it pops out.
2.
Unscrew the nut to remove the cover of the external enclosure.
3.
Mount the external enclosure onto the surface by means of screws and dowels
(not included) adhering to the mounting dimensions shown in
Fig. 3
Mounting
dimensions - surface mounting.
MTY-7-15-AT
ELECTRONIC FAN SPEED