OPERATING CONDITIONS & REQUIREMENTS
Page 5
EN - English
·
OPERATING PRESSURE: min. 1,4 / max. 8,3 bar
-
this system is configured to perform optimally at an operating
pressure of 3 bar (±½ bar); in case of a lower or higher operating
pressure the performance may be affected negatively!
-
check water pressure regularly.
-
take into account that night time water pressure may be
considerably higher than day time water pressure.
-
install a pressure reducer ahead of the water softener if
necessary.
·
OPERATING TEMPERATURE: min. 2 / max. 48 °C
-
do not install the water softener in an environment where high
ambient temperatures (e.g. unvented boiler house) or freezing
temperatures can occur.
-
the water softener cannot be exposed to outdoor elements,
such as direct sunlight or atmospheric precipitation.
-
do not install the water softener too close to a water heater;
keep at least 3 m of piping between the outlet of the water
softener and the inlet of the water heater; water heaters can
sometimes transmit heat back down the cold pipe into the
control valve; always install a check valve at the outlet of the
water softener.
·
ELECTRICAL CONNECTION: 230V-50Hz
-
this water softener only works on 24VAC; it is equipped with a
230/24V-50Hz transformer; always use it in combination with
the supplied transformer.
-
make sure to plug the transformer into a power outlet, which is
installed in a dry location, with the proper rating and over-
current protection.
Содержание Chrono
Страница 2: ...EN English Page 3 FR Français Page 11 DE Deutsch Seite 19 NL Nederlands Pagina 27 ...
Страница 10: ...EN English Page 10 ...
Страница 18: ...FR Français Page 18 ...
Страница 26: ...DE Deutsch Seite 26 ...
Страница 34: ...NL Nederlands Pagina 34 ...
Страница 35: ...Manufactured Assembled by erie water treatment a division of Aquion Inc www eriewatertreatment com ...