CHAPTER 3: TECHNICAL DESCRIPTION
Page 21
A computer is connected to the logging facility to
configure the system and set the time/date clock. The
configuration is stored in the removable loggers non-
volatile memory which includes:
Number of sensors on Run A
Number of sensor on Run B
Sampling interval
Logger ID
Probe
Each EnviroSCAN/EasyAG probe comprises one or
more soil moisture sensors placed along a support
rod. The probe, usually with an array of multiple
sensors, is installed into a vertical PVC access tube at
representative locations.
During sampling the logger applies power to the
probes and a signal to power up (address) a particular
sensor. The address signal is processed by the
interface (5-wire board) which applies power down
one of the wires of the ribbon cable. The sensor that
has been addressed (via PCB link) picks up the power
from the ribbon cable and begins to oscillate
depending on moisture content of the soil. The signal
from the sensor (open collector 40 to 80 kHz) is
applied to a common wire on the ribbon cable back to
the interface board.
The 5-wire interface board converts the signal from
open collector to differential drivers (RS485 type) for
transmission back to the logger via probe cabling.
Sensor
The
principle
of
operation
of
the
EnviroSCAN/EasyAG soil moisture sensor is based
on capacitance.
A capacitor consists of two conductive plates
separated by an insulating material (dielectric). The
value of capacitance (C) is determined by the area of
the plates, distance between the plates and the
Содержание RT6
Страница 1: ...Sentek RT6 HARDWARE MANUAL Version 3 2 February 2011 ...
Страница 2: ......
Страница 4: ......
Страница 8: ...SENTEK Page 4 ...
Страница 30: ...SENTEK Page 26 ...
Страница 46: ...SENTEK Page 42 ...
Страница 50: ...SENTEK Page 46 ...
Страница 62: ...SENTEK Page 58 ...
Страница 63: ...APPENDIX A Page 59 APPENDIX A System Overview ...
Страница 64: ...SENTEK Page 60 ...
Страница 65: ...APPENDIX B Page 61 APPENDIX B System configuration examples ...
Страница 66: ...SENTEK Page 62 ...
Страница 67: ...APPENDIX C Page 63 APPENDIX C Probe configuration examples ...
Страница 68: ...SENTEK Page 64 ...
Страница 69: ...APPENDIX D Page 65 APPENDIX D Front panel visual ...
Страница 70: ...SENTEK Page 66 ...
Страница 71: ...APPENDIX E Page 67 APPENDIX E Overlay diagram RT6 Main Board Overlay ...
Страница 72: ...SENTEK Page 68 ...
Страница 73: ...APPENDIX F Page 69 APPENDIX F Cable Wiring Order 5 wire Connector ...
Страница 74: ...SENTEK Page 70 ...
Страница 78: ...SENTEK Page 74 ...
Страница 79: ...APPENDIX I Page 75 APPENDIX I RS485 connections RS485 Circuit Diagram RS485 Physical Connections ...
Страница 80: ...SENTEK Page 76 ...
Страница 82: ...SENTEK Page 78 ...