background image

                                     

Sensor Technologies America, Inc.

                         1345 Valwood Parkway, Suite 320 :: Carrollton, Texas  75006
Phone: (972) 481-9223 :: Fax: (972) 481-9209 :: Toll Free: 1 (877) - SENTECH (736-8324)

                                                

 www.SentechAmerica.com

1

STC-1100C & STC-1100D Series
Operating Manual
Rev. 0.2 - Updated September 26, 2005

                                     

Sensor Technologies America, Inc.

                         1345 Valwood Parkway, Suite 320 :: Carrollton, Texas  75006
Phone: (972) 481-9223 :: Fax: (972) 481-9209 :: Toll Free: 1 (877) - SENTECH (736-8324)

                                                

 www.SentechAmerica.com

Double Speed

B&W Progressive Scan Camera

with

Variable Integration Random Shutter Trigger

and Vertical Reset

STC-1100C & STC-1100D

Operating Manual

(Positive Enabled Trigger Pulse Input)

(Negative Enabled Trigger Pulse Input)

Содержание STC-1100C

Страница 1: ... 0 2 Updated September 26 2005 Sensor Technologies America Inc 1345 Valwood Parkway Suite 320 Carrollton Texas 75006 Phone 972 481 9223 Fax 972 481 9209 Toll Free 1 877 SENTECH 736 8324 www SentechAmerica com Double Speed B W Progressive Scan Camera with Variable Integration Random Shutter Trigger and Vertical Reset STC 1100C STC 1100D Operating Manual Positive Enabled Trigger Pulse Input Negative...

Страница 2: ...Inc 1345 Valwood Parkway Suite 320 Carrollton Texas 75006 Phone 972 481 9223 Fax 972 481 9209 Toll Free 1 877 SENTECH 736 8324 www SentechAmerica com 2 STC 1100C STC 1100D Series Operating Manual Rev 0 2 Updated September 26 2005 ...

Страница 3: ...7 SENTECH 736 8324 www SentechAmerica com 3 STC 1100C STC 1100D Series Operating Manual Rev 0 2 Updated September 26 2005 Precaution 4 1 Specifications 5 2 12 Pin Connector 6 3 Switch Settings 7 4 Input Output Signals 10 5 Variable Integration Shutter Trigger Operations 11 6 Vertical Reset Operations 13 7 Dimensions 15 Table of Contents ...

Страница 4: ...n wet areas and do not expose camera to moisture Do not operate camera beyond its maximum operating temperature humidity and power source ratings To prevent dust or contamination from entering the CCD or filter area which could scratch or damage this area keep lens or lens cap on camera when camera is not in use Do not expose the camera to the following conditions Wet moist and or high humidity ar...

Страница 5: ...95 TVL Vertical Resolution 495 TVL Scanning System 525 Lines Progressive Scan or 2 1 Interlace Scanning Frequency Double Speed Pregressive 59 94Hz V 31 468KHz H Normal Speed Progressive 29 97Hz V 15 734KHz H Double Speed 2 1 Interlace 119 88Hz V 31 468KHz H Normal Speed 2 1 Interlace 59 94Hz V 15 734KHz H Minimum Illumination Normal Speed 1 Lux F1 4 Double Speed 2 Lux F1 4 S N Ratio 56dB Gamma 0 4...

Страница 6: ...Vdc 12Vdc 12Vdc 3 Video GND Video GND Video GND 4 Video Out Video Out Video Out 5 HD GND HD GND HD GND 6 Int HD Out Ext HD In Ext HD In 7 Int VD Out Ext VD In 8 M Trig GND 9 M Trig In 10 GND GND 11 12 VD GND VD GND GND Notes 1 Internal Sync Mode or External Sync Mode can be selected by the switch described in 3b When the External Sync Mode is selected and no external horizontal drive signal HD is ...

Страница 7: ...rollton Texas 75006 Phone 972 481 9223 Fax 972 481 9209 Toll Free 1 877 SENTECH 736 8324 www SentechAmerica com 7 STC 1100C STC 1100D Series Operating Manual Rev 0 2 Updated September 26 2005 3 Switch Settings a Fixed Manual Gain Switch b Sync Mode Switch c DIP Switch ...

Страница 8: ...Shutter Trigger Mode Switch Number Shutter Speed Sec 5 6 7 8 9 Normal Speed Double Speed Flicker Less ON ON 1 100 1 200 OFF OFF OFF Shutter OFF Note 1 Shutter OFF Note 2 ON OFF OFF OFF OFF 1 60 1 120 ON OFF ON OFF OFF 1 125 1 250 High Speed ON OFF OFF ON OFF 1 250 1 500 Shutter ON OFF ON ON OFF 1 500 1 1000 ON OFF OFF OFF ON 1 1000 1 2000 ON OFF ON OFF ON 1 2000 1 4000 ON OFF OFF ON ON 1 4000 1 80...

Страница 9: ...36 8324 www SentechAmerica com 9 STC 1100C STC 1100D Series Operating Manual Rev 0 2 Updated September 26 2005 f Input Signal Impedence Switch Notes 1 This impedence switch controls both HD and VD input impedence 2 Set this switch to High Impedence when the camera is used in the variable integration shutter trigger mode g Camera Correction Switch ...

Страница 10: ...ency 29 97Hz Normal Speed Progressive 59 94Hz Double Speed Progressive 59 94Hz Normal Speed 2 1 Interlace 119 88Hz Double Speed 2 1 Interlace b Sync Output Signals I HD Input Signal Level 2 5Vp p at 75Ω termination 5 Vp p at high impedence Termination Impedence 75Ω or high impedence Sync Frequency 15 734KHz 1 Normal Speed Progressive 31 468KHz 1 Double Speed Progressive 15 734KHz 1 Normal Speed 2 ...

Страница 11: ...dge see the drawing below Since XSUB is activated in the camera at the falling edge of the trigger pulse and XSG is activated at the rising edge the integration time is controlled very accurately Video signal output is sent out frm the camera at the moment t2 period ends t2 starts at the rising edge of the trigger pulse and ends at the 18th internal HD pulse 2 1 Interlace Mode or 33rd internal HD ...

Страница 12: ...50µmsec 8 3msec c t1 From the rising edge of the trigger pulse to the vertical sync pulse Normal Speed Interlace 4H Td 19H with HD synchronized trigger Normal Speed Progressive 4H Td 5H with HD synchronized trigger Double Speed Progressive 4H Td 5H with HD synchronized trigger d t2 From the rising edge of the trigger pulse to the video out Normal Speed Interlace 18H Td 19H with HD synchronized tri...

Страница 13: ...field of video signal 2 1 Interlace mode or one frame of video signal progressive mode is sent out 1 Turn Sync Mode Switch 2 b to External Sync 2 Turn DIP switch No 2 2 C II to ON Internal or External Sync The camera switches to external mode automatically when external HD is supplied 3 The vertical operates as Direct Reset Mode 4 In the case of 2 1 Interlace even odd field is determined by the ti...

Страница 14: ... STC 1100C STC 1100D Series Operating Manual Rev 0 2 Updated September 26 2005 Note Field odd or even determination Sign Definition Normal Speed Double Speed tp1 Area to reset to Odd Field 21 9µs 11µs tp2 Area to reset to Even Field 31 6µs 15 8µs tp3 Area to reset to Odd Field tp4 Prohibited Area 200ns 100ns tp5 Prohibited Area 200ns 100ns Normal and Double Speed Progressive Scan ...

Страница 15: ... Suite 320 Carrollton Texas 75006 Phone 972 481 9223 Fax 972 481 9209 Toll Free 1 877 SENTECH 736 8324 www SentechAmerica com 15 STC 1100C STC 1100D Series Operating Manual Rev 0 2 Updated September 26 2005 7 Dimensions Note Measurements are given in mm ...