No.14S056-01
48
STC-CMC120APCL, STC-CMB120APCL
Specifications and Users guide
Command No.
Command Descriptions
A0H:
VAHA[7..0]
A1H:
VAHA[15..8]
[Vertical AOI Effective Line AOI_A] Initial data: VAHA[15..0] = 3,072
、
Range: 4 to 3,072
This command sets the number of the effective lines (image height) of the variable partial scanning.
The value should be set to 4 Lines each.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
greater than 3072.
A2H:
VAHB[7..0]
A3H:
VAHB[15..8]
[Vertical AOI Effective Line AOI_B] Initial data: VAHB[15..0] = 3,072
、
Range: 4 to 3,072
This command sets the number of the effective lines (image height) of the variable partial scanning.
The value should be set to 4 Lines each.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
greater than 3072.
A4H:
VAHC[7..0]
A5H:
VAHC[15..8]
[Vertical AOI Effective Line AOI_C] Initial data: VAHC[15..0] = 3,072
、
Range: 4 to 3,072
This command sets the number of the effective lines (image height) of the variable partial scanning.
The value should be set to 4 Lines each.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
greater than 3072.
A6H:
VAHD[7..0]
A7H:
VAHD[15..8]
[Vertical AOI Effective Line AOI_D] Initial data: VAHD[15..0] = 3,072
、
Range: 4 to 3,072
This command sets the number of the effective lines (image height) of the variable partial scanning.
The value should be set to 4 Lines each.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
greater than 3072.
A8H:
VAHE[7..0]
A9H:
VAHE[15..8]
[Vertical AOI Effective Line AOI_E] Initial data: VAHE[15..0] = 3,072
、
Range: 4 to 3,072
This command sets the number of the effective lines (image height) of the variable partial scanning.
The value should be set to 4 Lines each.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
greater than 3072.
AAH:
VAHF[7..0]
ABH:
VAHF[15..8]
[Vertical AOI Effective Line AOI_F] Initial data: VAHF[15..0] = 3,072
、
Range: 4 to 3,072
This command sets the number of the effective lines (image height) of the variable partial scanning.
The value should be set to 4 Lines each.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
greater than 3072.
ACH:
VAHG[7..0]
ADH:
VAHG[15..8]
[Vertical AOI Effective Line AOI_G] Initial data: VAHG[15..0] = 3,072
、
Range: 4 to 3,072
This command sets the number of the effective lines (image height) of the variable partial scanning.
The value should be set to 4 Lines each.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
greater than 3072.
AEH:
VAHH[7..0]
AFH:
VAHH[15..8]
[Vertical AOI Effective Line AOI_H] Initial data: VAHH[15..0] = 3,072
、
Range: 4 to 3,072
This command sets the number of the effective lines (image height) of the variable partial scanning.
The value should be set to 4 Lines each.
The camera works with full scanning, when the total effective lines of the eight partial.
(VAHA [] + VAHB[] + VAHC[] + VAHD[] + VAHE[] + VAHF[] + VAHG[] + VAHH[]) is
greater than 3072.