Rev: 11/01/2012 

 

4-20mA or 0-10V Options 

 

 

Ref.: CARD-CDL-10 

 

 

RS232 options   

 

 

 

Ref.: CARD-CDC-20 

RS485 options   

 

 

 

Ref.: CARD-CDC-10 

IP65 protective cover options    

 

Ref.: COVER-PAX 

 

5.

 

SPECIFICATIONS 

Display 

5 red LED digits 14,2mm (-19999 à 99999) 

AC Versions 

85 to 250VAC 

50/60Hz 
15VA 
Isolation : 2300 Vrms for 1 min. to all inputs and outputs 
Operating  temperature :  0  to  50°C  (45°C  if  3  plug-in  cards  are 

installed) 

24VAC 

50/60Hz 
15VA 
Isolation : 500 Vrms for 1 min. to all inputs and outputs 
Operating  temperature :  0  to  50°C  (45°C  if  3  plug-in  cards  are 

installed) 

DC Version 

11 to 36VDC 

11W 
Operating  temperature  below  40°C  if  the  power  supply  is  below 

15VDC and 3 plug-in cards are installed 

Analog/digital 

converter 

16bits resolution 

Bridge excitation 

Jumper selectable 

5VDC, 65mA max, +/-2% 
10VDC, 125mA max, +/-2% 

Temperature coefficient (ratio metric): 20ppm/°C max 

Custom 

linearization 

Data point pairs 

Selectable from 2 to 16 

Display range 

from -19999 to 99999 

Decimal point 

0 to 0.0000 

Memory 

Nonvolatile EEPROM retains all programmable parameters and display values. 

Certifications  and 

compliances 

Electromagnetic immunity:  

Conform to EN 50082-2 

Electrostatic discharge 

EN 61000 - 4 - 2  

Level 3: 8 kV air 

Electromagnetic RF fields 

EN 61000 - 4 - 3 

Level 3: 10 V/m 80 MHz to 1GHz 

Fast transients (burst) 

EN 61000 - 4 - 4 

Level 3: 2 kV power 
Level 4: 2 kV (I/O) 

RF conducted interference 

EN 61000 - 4 - 6 

Level 3: 10 Vrms de 150 kHz - 80 Mhz 

Electromagnetic emission: 

Conform to EN 50081 -2 

RF interference 

EN 55011 

Enclosure class A 
Power mains class A 

Notes: Self-recoverable loss of performance during electromagnetic interference (EMI) at 10 V/m: 

measurement error exceeds unit specifications. For operation without loss of performance: 

- mount unit in a sheet-metal enclosure (Buckeye SM7013-0 or equivalent) 

- route power and I/O cables in metal conduit connected to earth ground. 
For more information, refer to guide treatment against the effects of EMC. 

 
Note : In load limitation operation, always lock the device configuration with an access code (the access code 

set at the SENSY factory is “7”). 

Содержание CRANE-BOY

Страница 1: ...limiter 4 2 2 2 2 Configuration of the triggering thresholds set points 5 2 3 Correct operation test 6 2 3 1 Verification of safety if one of the transducer wires breaks 6 2 3 2 Overload slack cable and load verification 7 2 3 3 Periodic verification 7 2 3 4 Peak values registration 7 3 TROUBLESHOOTING 8 4 EQUIPMENT REFERENCE AND OPTIONS 8 5 SPECIFICATIONS 9 This indicator can only be used for lif...

Страница 2: ... supply cable and or in the transducer measuring cable the device instantly switches into a positive safety mode It is possible to incorporate as options an analogue output 4 20 mA or 0 10V and serial communication RS232 All available options are listed at the end of the manual 1 2 Principle The CRANE BOY is fitted with a 4 relay board that must be used according to the wiring diagram described be...

Страница 3: ... keys to go up down and increase decrease The RST key in combination with F1 and F2 keys to increase decrease in steps of 1000 direct action on the fourth digit The DSP key to quit To enter the menus press the PAR key several times until CodE appears Then using the F1 key enter the value of 7 then press the PAR key No and Pro will then appear You can move from one menu to another using the F1 and ...

Страница 4: ...tabilise it mechanically Enter menu 1 INP using SENSY access code 7 and carry out the following operations using the PAR key to move on to the next parameter DISPLAY PARAMETER FACTORY SETTING USER SETTING rANGE INPUT RANGE 0 02u 0 02 dECPT DISPLAY RESOLUTION 0 0 round DISPLAY ROUNDING INCREMENT 0 1 FILtr FILTER SETTING 1 0 1 0 bANd FILTER ENABLE BAND 5 0 5 0 Pts SCALING POINTS 2 2 StyLE SCALING ST...

Страница 5: ...rown wire breaks SP2 must be reserved for load limitation its SP 2 and HYS 2 values will eventually be readjusted to the characteristics of the transducer s Wheatstone bridge if this was not carried out at SENSY s factory SP3 is factory set to be used for cable slack its SP 3 and HYS 3 values will eventually be readjusted to the characteristics of the transducer s Wheatstone bridge if this was not...

Страница 6: ...resis value 4 tON SP2 activation delay may be modified if the action of lifting a load that is less than the limit load generates forces dynamic movements of the load or the yo yo effect that are greater than those generated by the static limit load 5 Load below which lowering must be prohibited the SP3 relay opens After configuring and validating the parameters of your CRANE BOY return to display...

Страница 7: ...est button is fitted on the load limiter which destabilises the signal from the force transducer and simulates an overload The display offset generated by this test button must be identical to the offset that was obtained when the equipment was installed and recorded on the calibration sheet Push button in the OEM version connect the special push button supplied by SENSY between the signal and pow...

Страница 8: ... CRANE BOY for repair Parameter list memory fault One or more of set up parameters has changed value due to possible electrical glitch or loss of power during parameter save operation during End display Verify all set up parameters exit parameter set up mode and cycle power the meter to clear error If the error remains return meter for repair Calibration memory fault Verify calibration accuracy of...

Страница 9: ...y range from 19999 to 99999 Decimal point 0 to 0 0000 Memory Nonvolatile EEPROM retains all programmable parameters and display values Certifications and compliances Electromagnetic immunity Conform to EN 50082 2 Electrostatic discharge EN 61000 4 2 Level 3 8 kV air Electromagnetic RF fields EN 61000 4 3 Level 3 10 V m 80 MHz to 1GHz Fast transients burst EN 61000 4 4 Level 3 2 kV power Level 4 2 ...

Страница 10: ...on interface Screw terminals or connector CARD CDC50 Profibus PAX s option card Profibus communication Transmission of data input output up to 84 bytes input output Avalable communication speed 9 6 KB to 12MB with automatic speed detection CARD CDL Analogue PAX s option card Analogue output 0 20 mA 4 20 mA or 0 10 VDC Resolution 1 3500 CARD CDS Set point PAX s option card Relay output 2 versions 2...

Отзывы: