Network Wiring (MX-5000 Series)
2 - 28 • • • MPS-4100 product guide
Network Wiring (MX-5000 Series)
The optional MPS-4100 network transponder enables the MPS-4100 Microwave
system to communicate on the MX-5000 multiplex data bus. Installed directly on
the MPS-4100 Receiver unit PCB, the card provides network communications
through a two wire data bus, which connects to TB1 (Data/Test). One or two
Microwave sets can report to the MX-5000 Series Control Center via one
transponder card. For dual zone reporting, the Receiver, which includes the
transponder card is designated as the Host Receiver. The second Microwave pair
is configured as a Relay output version, and wires into the Host Receiver as a
Slave.
Setup all tamper and alarm relays as NC with 3 k
Ω
resistor
supervision.
Transmitter
For the Host or Slave Transmitter, follow the instructions for Relay Output Wiring.
The Host Transmitter wires to the Host Receiver, the Slave Transmitter wires to
the Slave Receiver.
Host Receiver
1. Connect the audio, power, and data pairs from the shielded interconnect
cable to TB1 (see Figure 2-23). See the note below regarding shield
terminations.
Observe Polarity
.
All shields should be clipped and taped off including the
overall shield. Incoming and outgoing cable shields should be
connected and taped off. DO NOT ALLOW THE INDIVIDUAL
PAIR SHIELDS TO TOUCH EACH OTHER OR THE OVERALL
SHIELD.
2. Connect the Host Transmitter power and tamper pairs to TB2. Power for the
Slave Receiver also connects to TB2.
The tamper input from the Transmitter must be NC.
If the Transmitter tamper is not being connected to the
Receiver, a jumper must be placed across TB2-3 & 4.
WARNING: Disconnect the power source to the MPS-4100 microwave before
installing the card
.
CAUTION: Observe proper ESD handling procedures when working on the card
.
CAUTION: It requires considerable force to install the interface card on P1 of the
MPS-4100 receiver
. Apply firm, even pressure along the card edge
while installing the card. Avoid twisting the card or uneven pressure.