Pelco 9750/9760
a - 4 • • • Senstar 100 Installation guide
Pelco 9750/9760
Senstar 100 default communication parameters and setup information
* There is no default setting for the Comm Timeout parameter. The Comm
Timeout parameter specifies how much time (in seconds) can pass without
communication between the Senstar 100 and the video switcher, before a
Comm Fail alarm is declared. A setting of 0 disables Comm Fail monitoring. The
Senstar 100 polls the device four times during each timeout period (i.e., if the
Comm Timeout is set to 20 seconds, the Senstar 100 will poll the video
switcher every five seconds).
Baud Rate
9600
Required Setup Information
Data Bits
8
Port Definition
Equipment Number
100
Parity
None
KBD Number
95/96
Stop Bits
1
Monitor Definition
Keyboard Access
to keyboards 95
& 96
Flow Control
None
Camera Definition
Open Access To
95 & 96
Comm Timeout
0 - 90 seconds *
Operators 95 & 96 Pin 5572
priority 1