SENSORWORX SWX-950 Скачать руководство пользователя страница 1

WIRELESS POWER PACK

LOAD  CONTROLLER   

INSTALLATION & OPERATION INSTRUCTIONS

CATALOG NUMBERS

DESCRIPTIONS

SWX-950

POWER PACK LOAD CONTROLLER

SWX-950-D2

POWER PACK LOAD CONTROLLER W/ 0-10V 
DIMMING

SWX-950-AX

POWER PACK LOAD CONTROLLER W/ AUXILIARY 
LOW VOLTAGE CONTROL

SWX-950-AX-D2

POWER PACK LOAD CONTROLLER W/ 0-10V 
DIMMING & AUXILIARY LOW VOLTAGE CONTROL

SWX-999

LOW VOLTAGE WIRING CHAMBER

SPECIFICATIONS 

ELECTRICAL

OPERATING VOLTAGE

120/277 VAC, 

Single Phase, 50/60 Hz

CLASS 2 OUTPUT RATINGS

18 VDC, 150 mA (-AX version)

RELAY CURRENT REQS

55 mA

LOAD RATINGS 

20A @ 120 VAC - 

General Purpose Plug Load
 20A @ 120/277 VAC -  

General Purpose, Tungsten, Magnetic 

Ballast
 16A @ 120/277 VAC -  

Electronic Ballast, LED Driver

DC LOAD RATINGS 

 20A @ 28 VDC (MAX)  

  1A @ 5 VDC (MIN)

DIMMING LOAD 

(Models with -

D2 

option only)

50mA, (0-10 VDC ballasts or drivers 

compliant with IEC 60929 Annex E.2)

MOTOR LOAD

1 HP

ESD IMMUNITY

Tested to withstand electrostatic 

discharge without damage or memory 

loss

ENVIRONMENTAL

OPERATING TEMP

32°F to 122°F (0°C to 50°C)

RELATIVE HUMIDITY

0-95% Non-Condensing 

Indoor Use Only

WIRELESS

RANGE

80’ line of site w/o obstruction 

40’ with obstruction (walls/floors)

FREQUENCY    

915 MHz ISM Band 

WIRELESS LINKING

Simple 3 sec. Push Button Process

SECURITY

All Wireless Data is Encrypted

PHYSICAL

SIZE

3.00” H x 2.25” W x 1.88” D 

(7.62 cm x 5.72 cm x 4.78 cm)

WEIGHT 

6.00 oz.

COLOR

Blue

MOUNTING

1/2” Knockout

RELAY TEST BUTTON

LED STATUS INDICATOR

Bi-color White & Blue

OPERATION

OPERATING MODES

 Occupancy & Vacancy

Partial On/Off (-D option)

TIME DELAY OPTIONS

1, 5, 10, 15, 20, 30 min.

CODE COMPLIANCE

These power packs can be used to 
meet ASHRAE 90.1, IECC, & Title 24 
energy code requirements

FEATURES 

 

Ã

Wirelessly Links to Sensors & Wall 
Stations

 

Ã

Pairs in Seconds up to 50 Remote 
Devices

 

Ã

Switches Up to 20A Line Voltage 
Loads

 

Ã

Electronically Timed Switching 
Ensures Long Relay Life 

 

Ã

Integrated Test/Programming Button

 

Ã

Configurable Time Delays and 
Operational Modes (e.g. Occupancy/ 
Vacancy)

 

Ã

Optional 0-10V Dimming Output for 
Partial On & Partial Off Operation

 

Ã

Optional Low Voltage Sensor & Wall 
Station Wired Connectivity

 

Ã

Plenum Rated (UL 2043)

OVERVIEW 

SENSOR

WORX wireless power pack controllers switch on/off power to a connected lighting 

load as directed by wirelessly linked sensors and wall controls. Additionally, the unit’s 
0-10V dimming option enables dimming control. This wireless power pack also has optional 
auxiliary low voltage connections for achieving hybrid wired/wireless architectures.

The 

SENSOR

WORX wireless power pack is rated to switch fully loaded circuits and utilizes 

a powerful microprocessor to optimize its switching timing, ensuring long relay life even 
when controlling high-inrush LED lighting. As with all 

SENSOR

WORX products, these power 

packs are easy to install and incorporate features which reduce contractor labor time. An 
elongated chase nipple with snaps for quick installation and an optional snap-on low voltage 
wire chamber make for a hassle free contractor experience. All 

SENSOR

WORX products are 

proudly made in the USA. 

BASIC OPERATION 

A received wireless message indicating occupancy from one or more wirelessly linked 
sensors will trigger the pack’s integrated relay to close. When configured for Vacancy 
operation, an ON switch message is required from a wirelessly linked wall station to initially 
trigger lights. Once closed, line voltage will flow through the relay and turn on the connected 
lighting load. The wireless power pack maintains a master time delay that is reset every 
time a linked sensor reports occupancy. Lights will be switched off once there hasn’t been an 
occupancy message reported for the duration of the time delay. 

Содержание SWX-950

Страница 1: ...p to 50 Remote Devices à Switches Up to 20A Line Voltage Loads à Electronically Timed Switching Ensures Long Relay Life à Integrated Test Programming Button à Configurable Time Delays and Operational Modes e g Occupancy Vacancy à Optional 0 10V Dimming Output for Partial On Partial Off Operation à Optional Low Voltage Sensor Wall Station Wired Connectivity à Plenum Rated UL 2043 OVERVIEW SENSORWOR...

Страница 2: ...ple as Class 1 circuits 2 Suitable for plenum use 3 Risk of Electric Shock More than one disconnect switch may be required to de engergize the equipment before servicing WARNING TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE WIRING BLU YEL BLK BLU WHT N 277V 120V OR CAP UNUSED BLACK OR YELLOW WIRE LOAD 120V 277V SWX 950 WIRELESS POWER PACK BLK COMMON 0 10V DIMMING OUTPUT VIO BLU YEL BLK BLU WHT N 27...

Страница 3: ...WER REQUIRED 15 30mA 0 0 0 0 30mA 90mA 15 30mA 0 0 1 55mA 85mA 90mA 0 0 9 90mA 0 0 90mA 90mA 7 14mA 8 80mA 0 0 94mA 90mA POWER PACK CAPACITY or low voltage wall switches EXAMPLE COMBINATIONS COMPATIBLE WIRELESS DEVICES MODEL DESCRIPTION WIRELESS TYPE POWER TYPE SWX 201 B Small Motion 360 Sensor PIR Transmit Battery SWX 401 B Wide View Sensor PIR Transmit Battery SWX 402 B Long Range Hallway Sensor...

Страница 4: ...he full bright level when occupied and dropped to the 50 level is configurable during unoccupied periods à Partial On operation can be achieved by the SWX 950 D2 unit In this configuration 0 10V lighting is turned on to a configurable Partial On Level when triggered from an occupancy sensor or switch Lighting can then be adjusted to any level via a wirelessly linked SWX 854 B remote dimmer Alterna...

Страница 5: ...ccupancy Lights will be switched off once all linked sensors have continously reported unoccupied for the duration of the time delay à If a power pack does not receive a heartbeat transmission from a linked sensor for 2 minutes it will consider itself occupied SWX 950 series power packs have many configurable functions depending on the specific model All functions setting values can be accessed an...

Страница 6: ...sequence of operation choices CHANGING THE OPERATIONAL MODE 1 Read through the above list and note the number of the desired setting e g 2 Automatic On Occupancy Mode 2 Press and release the unit s pushbutton 3 times then wait 2 seconds The White LED will blink back the number of the current setting repeats 3x before exiting 3 Interrupt blink back by pressing the button the number times equal to t...

Страница 7: ... setting is only active when the unit s Turn Off Scheme is set to Dim to Low Trim SETTING VALUES NOTES 2 0 VDC Exact light output at each voltage level depends on driver ballast and luminaire 3 1 VDC 10 4 2 VDC 20 5 3 VDC 30 default 6 4 VDC 40 7 5 VDC 50 FUNCTION 9 FADE OFF TIME SETTING VALUES NOTES 2 0 75 Sec 3 1 5 Sec default 4 3 Sec 5 5 Sec 6 15 Sec FUNCTION 10 FADE ON TIME SETTING VALUES NOTES...

Страница 8: ...re requirements this device must be installed to provide at least 20 cm separation from the human body at all times This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and...

Отзывы: