11
USB Data Logger
Operation Manual
Rev 1.5
Operation Manual of USB Data Logger
--------P.7-----
Version:1.30
Get current setup information from the logger. Click this button, and then the old setup
information is shown below.
In the example below, the settings are as follows:
: Synchronize the new setup information and current PC time to the logger. After changing the
configuration,
do not forget
clicking this button to make sure that the new configuration is wrote to
the logger.
: Synchronize the PC time to the logger.
Name: Gives a name to the logger.
Type: The device type.
Model: The device model.
Serial No: Every logger has a SN with 10 characters. The length must be 10.
LOG Intervals(s): The interval of recording.
Log Count: The count of the logs that the logger has recorded.
Memory capacity: The total capacity of the logger memory. One reading includes time and three
channels’ data.
Temperature Unit: The selection of C and F.
Start Mode: There are three start modes: No Delay / Delay / Timer.
Synchronize the PC time to the logger
Name:
Gives a name to the logger.
Type:
The device type.
Model:
The device model.
Serial No:
Every logger has a SN with 10 characters. The length must be 10.
LOG Interval(s):
The interval of recording.
Log Count:
The count of the logs that the logger has recorded.
Memory Capactiy:
The total capacity of the logger memory. One reading includes
time and three channel’s data.
Temperature Unit:
The select of C and F.
Start Mode:
There are 3 start modes: No Delay/Delay/Timer.
No Delay:
The logger will start to log immediately
Delay:
The logger will start to log after a delay time
Timer:
The logger will start to log at a specific time
Note: If the logger is OFF, the logger cannot record any logs.
Calibrate the logger:
The logger is factory calibrated to an accuracy given in the
device specifications. However, there may be times when you wish to adjust the
calibration of your logger. ToAnalyzer provides you with the ability to perform a
single point offset calibration. This calibration can be used to increase the accuracy
of the logger for a restricted data range.
CH1 offset:
The offset of channel 1.
CH2 offset:
The offset of channel 2 (if the logger is temperature logger, the CH2 and
CH3 are useless).
CH3 offset:
The offset of Dew Point.