Amcorders are designed for use on live, overhead lines with 0 to 69KV. All 
procedures ap pro pri ate for the line voltage are to be taken, including proper 
work techniques, equipment, and Personal Protection Equipment.

The Amcorder should be deployed and retrieved only by certifi ed personnel 
who have been trained for live-line, high voltage work by their organization.

The Amcorder is to be installed and removed from the line with a suitable 
shotgun or switch stick style hot stick. The hot stick is considered the sole 
voltage isolation device. 

The hot stick length must be correct for line voltage per minimum approach 
distances stated in published OSHA regulations and/or provided by the utility.

The cover plate, chuck, and entire Amcorder are to be considered at the same 
potential. Putting the cover plate, chuck, or other parts of the Amcorder 
within the air gap of adjacent phases or ground could cause a phase to phase 
or phase to ground fault.

Do not alter the product in any manner.

Theory of Operation

The Amcorder deploys on a line to measure and record True RMS Amps on overhead 
lines. The Amcorder uses the same current sensor technology as the original 
SensorLink

®

 Ampstik

®

, which does not use magnetic materials and has no moving 

parts. Measurements are taken at user defi ned intervals. In Softlink software the 
user selects how often to sample and log the data. 
Remove the units from the line to download the data via IrDA. Data can be 
downloaded via radio with the unit deployed on the line with the optional Radio 
Transcorder.

Page 5

Содержание 920 FRG

Страница 1: ...Operators Manual Recording Ammeter Amcorder SensorLink...

Страница 2: ...Adapter Model 7 053 Qty 1 sold in 6 920 1 Kit Qty 1 sold in 6 920 3 Kit Universal Switch Stick Receiver Model 7 054 Qty 1 sold in 6 920 1 Kit Qty 3 sold in 6 920 3 Kit Carrying Case Model 659 Qty 1 s...

Страница 3: ...cement and Operation 7 Installing on a Line Installing on a line with a Shotgun Hot Stick 8 Installing on a line with a Universal Switch Stick Hot Stick 9 Warranty 19 Quality Assurance Back Cover Soft...

Страница 4: ...3 in 24 77 cm x 12 07 cm x 7 62 cm Housing Shock and water resistant molded urethane Operating Temperature 22 to 140 F 30 to 60 C Lithium battery required for temperatures below 4 F 20 C Storage Temp...

Страница 5: ...oltage per minimum approach distances stated in published OSHA regulations and or provided by the utility The cover plate chuck and entire Amcorder are to be considered at the same potential Putting t...

Страница 6: ...ning The Recorder should be cleaned by wiping with a silicone hot stick wipe to remove dirt sand and salt that will degrade the urethane housing Sample and Log Intervals Sample and Log Interval The Sa...

Страница 7: ...sure the reliability of the battery life The Recorder will stop operating when the battery fails to supply more than five volts All the logged data is safely stored in flash memory When a fresh batter...

Страница 8: ...ck Shotgun Adapter Urethane Springs Urethane Carabineer Do not install on angled or vertical overhead lines The clamping mechanism is not designed for these lines and doing so will cause the unit to m...

Страница 9: ...rt the adapter into the receiver and then twist until the adapter locks into the receiver Step 4 Place the Amcorder on the conductor Step 5 Pull down on the unit to ensure that the urethane springs ar...

Страница 10: ...your network administrator for permission and instructions to complete the install if drivers are not installing automatically Softlink Installation Step 1 Softlink Installer is available at www senso...

Страница 11: ...has been discovered Communicating with Recorder Softlink communicates with one Recorder at a time To make sure only one Recorder is communicating stand any other Recorders on their base To communicate...

Страница 12: ...scroll bar Battery life depends on this setting see page four Synchronization Selecting the Clear all logged data from the Recorder and synchronize logging to the hour box will allow the Recorder to...

Страница 13: ...nload the data from any additional units Each unit s data will load into a new tab NOTE Once a fresh battery is inserted the user has 5 minutes to start downloading the data before the Amcorder resets...

Страница 14: ...uture review in Softlink or another data management program The data from each recorder is saved into its own file Step 1 Select the data file by selecting the Recorder on the menu Step 2 Select save...

Страница 15: ...opening saved files Step 1 Open Softlink Step 2 Close the Discovering ports and instruments bar Step 2 Select Open File Step 3 Find and select the csv or xlsx Softlink file Opening data files in other...

Страница 16: ...line thickness The thickness of the graph lines can be changed by the user Thickness is numbered 1 10 and defaults at three The software will show a preview to the user as the value is changed Chart...

Страница 17: ...ed measurement parameters will display on the graph Hide and Show Report Options Click the left arrow to hide Report Options Click the right arrow to show the hidden Report options Zoom Window The bot...

Страница 18: ...ay not work The IrDA you received with your kit has been tested to work with the Recorders 5 The Serial Number of the IrDA must start with a TA if running Softlink on WIN 10 6 Try restarting Softlink...

Страница 19: ...f the instrument 2 Subjected to misuse negligence or accident or 3 Connected installed adjusted or used otherwise than in accordance with the instructions furnished by SensorLink Corporation This Warr...

Страница 20: ...___________ I hereby certify that the Model 920 Amcorder has passed all tests defined in the SensorLink Corporation standard I also certify that I have reviewed the standard and test procedure and tha...

Отзывы: