3/5
1.
INSERTION OF BATTERIES
•
Open the battery compartment
•
Insert two AAA batteries as shown
•
Close the battery compartment
2.
REMOTE CONTROL OPERATION
0-9 Number keys (1)
Not used (2)
Plus (3)
Unlock (4)
Minus (5)
Holdtime (6)
Not used (7)
Not used (8)
Not used (9)
(10) Monitoring
(11) Detection field configuration
(12) Not used
(13) Pulse frequency
(14) Door control
(15) Check Values
(16) Lock
(17) Output configuration
(18) Maximum duration of presence detection
(19) Set-up
(20) Sensitivity (presence)
Remark: For optimum results point the remote control
vertically to the front of the sensor before pressing its
buttons. The sensor can be adjusted with or without its
cover from a distance of up to 2m.
3. CONFIGURATION OF THE SENSOR
Every adjustment session using the infrared remote control must start with unlocking and end locking. The table below lists the parameters able to be adjusted
by remote control and the operations required in order to adjust these parameters.
PARAMETERS OPERATIONS
LED
SIGNAL
UNLOCK
Press the UNLOCK key (4).
Enter your 4-digit access code using NUMBER keys 0-9 (1).
Press only the UNLOCK key (4) (no code required):
•
during the first sensor adjustment;
•
if the access code is reset to the "0000" value (factory setting);
•
during the first minute after the power-on.
UNLOCK with code
UNLOCK without code
The red LED flashes quickly waiting for the access
code.
After entering the correct code or if no code is
required, the red LED flashes slowly to indicate that
the unlock was successful and the adjustment
session has begun.
Note:
= Adjustment session ON
LOCK
When all the parameters have been set, press the LOCK key (10).
If you wish to enter a new access code, use NUMBER keys 0-9 (1) to enter the
new 4-digit code within 1 minute.
If no access code is entered or if you want to keep the current access code,
press the LOCK key (16) once more.
If no remote control key is pressed within 1 minute, the adjustment session is
automatically locked.
LOCK with code change
LOCK without code or code change
The red LED stops flashing and returns to its normal
function.
CONFIGURATION
WITH REMOTE
CONTROL