4

GREEN

BROWN

WHITE

YELLOW

PINK

VIOLET

RED

BLUE

WHITE/RED

WHITE/BLUE

POWER 
POWER SUPPLY  -

NOT USED

RELAY 2 - SAFETY FIELD

TEST +
TEST  -

NOT USED

No monitoring*: 

connect red and blue wires to power supply (no polarity)

MOuNTING

WIRING

Use the adhesive 

mounting template 

to position the sensor 

correctly. The grey area 

indicates the detection 

range.

Drill 4 holes as indicated 

on the mounting 

template. Make a hole 

for the cable if possible.

Pass the cable +/- 10 cm 

though the cable opening. 

If drilling an opening is 

not possible, use the cable 

conduits on the back side of 

the bracket.

Position the bracket 

and fasten the 4 screws 

firmly.

Open the protection 

cover, plug the 

connector and position 

the cable in the slit.

Close the protection 

cover and fasten it firmly.

Turn the sensor until the 

two triangles are face 

to face.

Position the housing on 

the bracket.

*for more info, please contact SENSORIO

INSTALLATION STEPS

Содержание LZR-W400

Страница 1: ...1 LZR W400 Laser scanner for THE SAFETY OF POWER OPERATED WINDOWS EN User s Guide for product version 0700 and more...

Страница 2: ...no power power Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manu...

Страница 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Страница 4: ...4 VERTICAL PROTECTION HORIZONTAL PROTECTION POSSIBLE APPLICATIONS...

Страница 5: ...Drill 4 holes as indicated on the mounting template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits o...

Страница 6: ...nal a fault in case the orientation of the sensor is changed on purpose or by accident Adjust the lateral position of the detection field Adjust the tilt angle of the detection field with the hex key...

Страница 7: ...and adapts the detection field shape to these Objects in the detection field will be cut out IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the de...

Страница 8: ...NTS OPTIONAL FACTORY VALUES Immunity filter MIN OBJECT SIZE OUTPUT CONFIGURATION approximate values A active P passive UNCOVERED ZONE off indoor outdoor low outdoor med outdoor high indoor outdoor low...

Страница 9: ...UES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote...

Страница 10: ...he power supply is inverted Check cable and connexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step...

Страница 11: ...W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V...

Страница 12: ...the other relevant provisions of the directives 2006 95 EC 2002 95 EC and 2004 108 EC Angleur November 2011 Jean Pierre Valkenberg authorized representative The complete declaration of conformity is a...

Отзывы: