background image

 

LZR -RS300

®

1

2

3

4

*Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer.

USER’S GUIDE

1. Relay 1 - Field 1
2. Relay 2 - Field 2
3. Error
4. Power

GREEN LED

RED LED

BLUE LED

ORANGE LED

LED 

FLASHES

QUICKLY

LED 

FLASHES 

NORMALLY

LED 

FLASHES 

SLOWLY

LED 
OFF

DETECTION

POWER ON

ERROR

NO

DETECTION

Adjustable bracket

Cable conduit

LED-signal

Visible
laser beams

Laser sweep
reception

Laser sweep
emission

Tilt angle

adjustments

Main
connector

Front screens

Caution! Exposure

 to laser radiation.

Factory values

LED-SIGNAL

USED SYMBOLS

DESCRIPTION

ENGLISH

SAFETY SENSOR FOR EXTERNAL RAILWAY DOORS*

Содержание LZR-RS300

Страница 1: ...ORANGE LED LED FLASHES QUICKLY LED FLASHES NORMALLY LED FLASHES SLOWLY LED OFF DETECTION POWER ON ERROR NO DETECTION Adjustable bracket Cable conduit LED signal Visible laser beams Laser sweep recept...

Страница 2: ...x output pulse power 75W Red laser CLASS 3R wavelength 650nm max output CW power 3mW Fasten the sensor firmly to avoid vibrations If the sensor is used in environments where the temperature can descen...

Страница 3: ...r the cable if possible Drill 4 holes as indicated on the mounting template Use the adhesive mounting template to position the sensor correctly The grey area indicates the detection range Position the...

Страница 4: ...the bracket to avoid malfunctioning To unlock use a screwdriver The beams will stay activated for 15 minutes or can be turned off the same way Mounting side 1 LEFT with background 2 RIGHT with backgro...

Страница 5: ...d 0 5 m 5 0 m Field 1 Field 2 0 5 m 5 0 m for a field width of 3 5 m only for field 2 1 Indoor 2 Outdoor LOW 3 Outdoor MEDIUM 4 Outdoor HIGH 1 Active NO 2 Passive NC 3 Passive NC 4 Active NO Passive N...

Страница 6: ...arameter Set value RED RED RED OFF Power supply OFF ON How to delete an access code RED RED OFF Select code 1 4 digits How to save an access code Enter code RED OFF RED RED 1 4 digits REMOTE CONTROL H...

Страница 7: ...ial in proximity to the sensor Verify the field size Check the position of the sensor Launch a new teach in Check mounting side setting If there is no background set the mounting side to value 3 to 5...

Страница 8: ...erminal 5 W 1 8 A max 80 ms 35 V 2 m typ 20 ms max 80 ms 2 electronic relays galvanic isolated polarity free 35 V DC 24 V AC 80 mA resistive t 5 ms t 5 ms ON OFF typ 30 0 7 V 20 mA 10 A 1 blue LED pow...

Отзывы: