background image

28 

4.6

 

 Settings 

 

Main OSD 

4.6.1

 

  

General setting

 

 

General setting OSD 

Press confirming key will pop up the panel and select the SETTING to open 

the main menu. Select the general setting in the main menu. General setting 

OSD will pop up after pressing confirming key. Users could set the time of auto 

calibration  /  definition  of  shortcut  key  /Bluetooth/pattern  of  power  saving/ 

brightness adjustment of LCD / unit of temperature / unit of distance/external 

video output switch .totally 8 items. Switch to items by pressing key of up or 

down. Change the value by pressing key of left or right. 

>

 means secondary 

-menu and enter the menu by pressing key of right .  

File management 

Image setting 

General setting 

SD card management 

Temperature measurement setting

 

Imaging setting 

Photo&video capturing 

System setting 

Содержание Thermoview P-64

Страница 1: ...Thermoview P 64 Thermal Image Camera User Manual Sensor Partners BV 2016 Sensor Partners...

Страница 2: ...wer off as damage may result to the thermal detector used inside Permanent damage may result CAUTION The original shipping carton should be kept for use for future transportation Do not drop shake or...

Страница 3: ...NOTE Each camera is factory calibrated It is recommended that calibration be performed every 12 months CAUTION Do not open case Unit does not contain any user serviceable parts Repair should be perfo...

Страница 4: ...asurement 18 3 3 3 Freeze and save image 20 3 3 4 Viewing stored Images 20 3 3 5 Export saved images 21 3 3 6 LED screen settings 21 3 3 7 Menu operating instructions 21 4 Operation guide 22 4 1 Graph...

Страница 5: ...8 System settings 39 4 7 File management 42 4 7 1 Playback 42 4 7 2 Delete 44 5 Specification 46 6 6 6 6 Troubleshooting 48 Appendix A 49 Common material emissivity FYI 49 Appendix B 50 Factory defau...

Страница 6: ...anguages 1 8 X digital zoom 10 removable spot measurements 5 areas measurements 2 lines measurements Shortcut key custom Auto focus Manual focus Bluetooth WIFI Power save mode LCD brightness adjustmen...

Страница 7: ...ate checking problem and defect diagnosis Electrical system Identify potential circuit overloads Mechanical system Reduce downtime and avoid catastrophic failure Construction science Roof Quick identi...

Страница 8: ...etection on specific materials of auto ignition Detection of potential spark ignition sources Medical Human body surface temperature detection and screening Petro chemical Oil pipeline status inspecti...

Страница 9: ...n batteries 2 Charging dock Lithium battery charger Lens cap User manual Infrared report and analysis software system CD SD card SD card reader Network cable Mini USB to RJ45 1 2 Optional accessories...

Страница 10: ...10 2 Camera overview 2 1 Function keys 4 5 2 3 1 9 8 10 6 7...

Страница 11: ...ter adding a spot or by selecting via the A key press the Menu key to pop up the attribute box Press four navigation keys to move the spot location In line temperature measurement editing mode activat...

Страница 12: ...ess the key twice to save the image In file management press the key to choose whether delete the chosen image or video 5 Select Auto key Marked A The A or attribute button performs 3 functions a The...

Страница 13: ...ed Key The standard configuration is to switch temperature range F1 F3 is user defined key except standard configuration it can define below functions Image playback record short press to enter image...

Страница 14: ...twork cable Minu USB to RJ45 to connect Internet 13 SD card slot Accepting standard size SD card such as supplied 8GB capacity card for device upgrade or image storage 14 Power interface External powe...

Страница 15: ...located at the end of the camera below the view finder Insert the battery the battery contacts must face into the battery compartment promote it until the battery lock is locked When inserting the ba...

Страница 16: ...se of incorrect battery may result in physical or electrical damage to the instrument due to incorrect voltage or physical size difference 3 1 2 Replacing battery When battery has approximately 5 char...

Страница 17: ...mmended that the battery should be charged in a set time as below Ambient temperature of 4 F 20 C to 67 9 F 20 C once every 6 months 67 9 F 20 C to 113 F 45 C once every 3 months 113 F 45 C to 149 F 6...

Страница 18: ...red please press button A for a long time to compulsion in force 3 3 2 Temperature measurement If no measurement cursors are on screen add a measurement spot area or line by pressing MENU and selectin...

Страница 19: ...log box Spot attributes can amend emissivity distance and reference temperature When Set Ref is set as Yes the displayed values of other measurements will be their delta from this measurement Line att...

Страница 20: ...nly select one reference temperature object 3 3 3 Freeze and save image There are three ways to save the image 1 Press S key to freeze the image and then select Save to save the image or select Cancel...

Страница 21: ...ust LED screen brightness 2 Set shortcut key to LCD brightness adjustment to adjust LED screen brightness 3 3 7 Menu operating instructions Keyboard operation press the OK button to pop up the floatin...

Страница 22: ...interface description 4 1 1 Screen graphic interface Screen graphic interface 1 Company logo 2 Emissivity the current emissivity setting 3 Reference Temperature Fixed reference temperature 4 Result I...

Страница 23: ...Palette palette bar User can choose different palettes 11 Calibration freeze indicate the calibration status or freeze status 12 WiFi WiFi is open will change along with WiFi signal 13 Bluetooth selec...

Страница 24: ...dding spot adding line adding area delete taking photo record playback and main menu 4 1 3 Main menu Main Menu The main menu items display the main menu item namely the document management temperature...

Страница 25: ...t each item corresponds to the content of a project the left and right keys to make changes indicates the lower menu 4 Parameter options press the left button to select a different parameter 4 2 Measu...

Страница 26: ...o save the video save format to MP4 Pressing the Enter key floating menu pops up select video and press the Enter key as shown below Recording Figure Press stop key to end the recording and return to...

Страница 27: ...4 5 Preview This item is for the preview files of backup Press confirming key Pop up the floating items select preview and press confirming key will appears as followed Preview OSD Switch to files by...

Страница 28: ...calibration definition of shortcut key Bluetooth pattern of power saving brightness adjustment of LCD unit of temperature unit of distance external video output switch totally 8 items Switch to items...

Страница 29: ...yback record LED light OLED light brightness adjustment transparency adjustment adding or delete spot adding or delete area options for choice When select shortcut key of light It will open the lighti...

Страница 30: ...key thermal imaging camera will screen on This function is not valid when time is set to 0 minute Time of power off If without any operation thermal imaging camera will power off to save power This f...

Страница 31: ...31 Auto off time OSD LCD brightness adjustment It is valid when changing the brightness LCD brightness adjust OSD...

Страница 32: ...stment object temperature can be set Use UP Down button to select means there is sub menu press Right Button to enter the sub menu Level Setting the Measuring Level of the thermal camera Magnification...

Страница 33: ...nu press Right Button to enter the sub menu Emissivity Different target has different emissivity so the user can set different emissivity for different target If it is not set then will use default se...

Страница 34: ...s purpose When Auto Enhance Mode is activated can switch between manual and automatic Press A button will enter manual mode it can adjust the pallet with UP Down LEFT Right buttons Press C will return...

Страница 35: ...mp alarm Low temp alarm here It will alarm when proper setting is selected Alarm color can be set in Alarm Color Alarm Color The color of the target area shown on the LCD will be changed into the alar...

Страница 36: ...ff disables the feature Isotherm low value Set the Isotherm low value Isotherm upper value Set the Isotherm upper value IR Fusion High Low temperature Menu IR Fusion High Low temperature It consists o...

Страница 37: ...ect Network function IP Address This IP address must be the only one can not be conflicted with the other IP address of the same network segment Sub network mask Divide the segment of the sub network...

Страница 38: ...ssing the confirm key to format press cancel or C key to cancel the formatting Note Verify that the file is no longer needed or have been backed up before formatting after formation the saved thermal...

Страница 39: ...ns is to add voice when you save the picture text annotation is to add text messages when save the image CS Shots Set Continuous capture the number of sheets can be set for 1 3 5 10 shot Continuous Ca...

Страница 40: ...date formats time date restore the factory value items Pressing the up down key to switch the setting use left and right arrow keys to set the contents of the setting The indicates that there s a lowe...

Страница 41: ...st the system time Restore the factory settings This function is used to restore the factory settings Pressing the confirmation button the setting menu will come up continue to press the confirm key s...

Страница 42: ...line is not more than 20 words After the import is complete restart the instrument to take effect Export TF card make sure the SD card is in the machine then select the menu and then click the Export...

Страница 43: ...ed image Pressing the C key to exit open image and return to the measurement state Preview Mode Figure 2 Preview mode press the OK button to pop up floating panel to select Preview option enter the pr...

Страница 44: ...y to take effect on the next key to show and hide the playback status bar press the on button is displayed press the next button is hidden The icon buttons from left to right is as follows the former...

Страница 45: ...45 File Delete Figure Note Before deletion make sure that the file is no longer needed or have backup the deleted image can not be recovered...

Страница 46: ...reading Whichever is greater Measurement correction Automatic manual Measurement mode Up to 10 movable spots Up to 5 movable areas maximum minimum and average temperature movable lines Line profile I...

Страница 47: ...able Battery operating time 3 hours continuous operation Battery charging mode Intelligent charger or power adaptor 12V optional to random charge Power saving Auto sleep and auto shut down External po...

Страница 48: ...Wait for 5 seconds and reboot The camera powers off automatically Battery is out of power Change battery AutoOffTime option is enabled Set as None Battery depletion is too fast Environmental temperatu...

Страница 49: ...0 21 Wrought iron Quarry faced 25 0 94 Polished 38 0 28 Nickel Oxidized 200 0 37 Stainless steel Oxidized 60 0 85 Steel Oxidized 200 0 79 Common brick Surface 20 0 93 Concrete Surface 20 0 92 Glass Po...

Страница 50: ...emperature correction table Parameter Value Emissivity 0 96 TCorrect 0 C TAmbient Temp Off Table 3 Analysis setting table Parameter Value Temp Alarm Off Alarming Temp 50 0 C Alarming Color None Isothe...

Отзывы: