LAM71, Release 001_Revision 001
37
Parameter MW (measurement window) and SA (mean value, average) will influence the output.
If the selected target will be outside of the range of measurement window the output will be not
a distance values
→
please see setting of MW parameter z.
6.6.15
TC
–
Time Calibration
Parameterises the time between 2 customized calibrations.
The calibration is necessary to stabilize the distance accuracy and to avoid a lower accuracy because of
temperature changes in the environmental of the electronic parts.
Query:
TC
Set:
TCx
Value range parameter x:
0
(no calibration),1… 3660 (seconds)
(= 1 sec up to 1 h interval)
Standard:
1
Up to a Measuring frequency of approx. 35 kHz the calibration will be done without any influences of
the output frequency.
Between 35 k Hz and 40 kHz it could be possible that the data output will interrupt for one (1) distance
output every x seconds (x= parameter of TC).