6.6.6
MW
–
Measurement window
This is for parameterising the range of a measurement window, starting with x and terminating with y.
Parameter z set the output value before and after the range of measurement window (MW).
Only those measured values are put out which are within the range of the measurement window.
For example, the measurement window can be used to:
-
Blank out interfering objects before and behind a measurement range
-
Determine a defined measurement range
An object detected before or behind the measurement window will generate the output of an invalid
measured value.
Query:
MW
Set:
MWx y z
Value range parameter x:
float32; resolution: 0.001 (= 1 mm)
Value range parameter y:
float32; resolution: 0.001 (= 1 mm)
Value range parameter z:
0 or 1
Standard:
-71.000 71.000 0
Output: MW -71.000 71.000 0
LAM71 does not perform a plausibility check of the preset measurement window. It is the responsibil-
ity of the user to set the correct parameters.
Output values:
Measuring window
distance < x
x < distance < y
distance > y
z = 0
DE02
Measuring value
DE02
z = 1
No output/ blanking pulse
Measuring value
No output/ blanking pulse