3.2
SensoRecord
When SensoRecord is called up by clicking on the respective tab, the user password is requested as the sensor’s
run mode must be interrupted to download images from the recorder.
With this module, the images defined in SensoConfig or here in SensoRecord (all images, error images,…) can be
loaded from the sensor on to the viewer, displayed and saved here if necessary.
The memory depth of the ring buffer is 30 images. Loading images on to the Viewer deletes them from the sensor. If
the SensoRecord window is quit without images having been stored, they will also be deleted from the memory here.
Fig. 10
155-01109
Get Mode
Requests the current recorder setting from the sensor, which involves interruption of run mode
… The identified mode is displayed in the “Recorder” combo box.
Set Mode
Opposite of "Get Mode" ... transfers the recorder mode set in the “Recorder” combo box to the
sensor, which also requires interruption of run mode.
Get Images
Calls up any recorder images stored on the sensor … which also requires interruption of run
mode.
Recorder
Combo box, which either displays the recorder setting in the sensor using Get Mode, or is
used as an input which is then transferred to the sensor using Set Mode.
Previous
Shows previous image
Next
Shows next image
Help
Calls up help
Save
Saves current image
Save all
Saves all images