Sensopart Vision Viewer CE Скачать руководство пользователя страница 22

Vision Viewer CE FA 45  GB - 068-14298 - 23.03.2010-00

Mounting and  

operating instructions

22

2.2 

Network settings

The following instructions indicate how to change the network configuration of the Vision Viewer 

CE and FA 45 Vision Sensor. If incorrect settings are used, network connections on the Vision 

Viewer CE can be lost. For safety purposes, old settings should be recorded and used again if 

necessary. It may be necessary to restart the system after these steps have been completed.

To find out which IP address is authorised in your network or locally on your Vision Viewer CE, 

and to carry out settings on your Vision Viewer CE, please first contact the responsible system 

administrator.

The illustrations, dialogue boxes and menus shown are taken from Microsoft Windows CE 

system software.

There are two basic possibilities for configuring the FA 45 Vision Sensor and setting 

parameters:

1. Direct connection

2. Network connection

2.2.1   Direct connection – Setting Vision Viewer CE’s IP address

To connect the FA 45 Vision Sensor to a computer via Ethernet, the IP address settings of both devices must 

correspond. The IP address in the Vision Viewer CE has the factory setting 192.168.100.101 with subnet mask = 

255.255.255.0. When connecting directly, the Vision Viewer CE must be set to a fixed IP address which matches the 

sensor, using the following procedure:

1.  Click on  Start 

 Settings 

 Control Panel 

 Network and Dial Up Connections 

 Network connection (here 

SMSC91181) 

 this opens the dialogue box „Internal Ethernet Driver Setting“

2.  Select the option “Specify an IP address“ and enter a suitable IP address and subnet mask. 

3.   Confirm entries with OK..

4.  After having changed the IP address, the Vision Viewer CE must be shut down with „Start“ and „Suspend“ in 

order to save the settings.

Example:

The FA 45 Vision Sensor is supplied with the IP address 

192.168.100.100  and subnet mask 255.255.255.0.

The IP address can in this example be selected between 

192.168.100.1 and 192.168.100.254 with the set subnet 

mask 255.255.255.0 - with the exception of the sensor’s IP 

address (192.168.100.100).

To alter the sensor’s IP address, see the chapter “Commis-

sioning” (FA 45 sensor’s mounting and

operating instructions)

Fig. 7

155-01130

Содержание Vision Viewer CE

Страница 1: ...ngsanleitung Mounting and operating instructions Instructions de service et de montage Vision Viewer CE Vision Viewer CE Vision Sensor FA 45 Vision Viewer CE Vision sensor FA 45 Vision Viewer CE Capte...

Страница 2: ...atsoever nor may illustrations drawings and the layout be copied without prior written permission from SensoPart Industriesensorik GmbH We accept no responsibility for printing errors and mistakes whi...

Страница 3: ...e 4 1 3 Lieferumfang 4 2 Funktionsbeschreibung 5 2 1 Eingaben am Ger t 7 2 2 Netzwerkeinstellungen 10 2 2 1 Direkter Anschluss Einstellen der IP Adresse des Vision Viewer CE 10 2 2 2 1 Netzwerkanschlu...

Страница 4: ...cherheitshinweise Vor der Inbetriebnahme des Vision Viewer CE diese Montage und Bedienungsanleitung insbesondere die Sicherheitshinweise lesen verstehen und unbedingt beachten Der Anschluss des Vision...

Страница 5: ...SHS4 FA 45 VGA CCD Mono Objekterkennung C CS Mount Objektiv High End EtherNet RS422 522 91054 FA 45 300 CR V5 Codereader FA 45 300 WCC CRO6 HS6 FA 45 Codereader Highend 6 mm Objektiv Wei licht 4 pol E...

Страница 6: ...EtherNet IP 522 91163 FA 45 300 RCC CRO6 ES7 FA 45 Codereader Extended Quality Parameters 6 mm Objektiv Rotlicht 4 pol EtherNet EtherNet IP 522 91164 FA 45 300 RCC CRO12 ES7 FA 45 Codereader Extended...

Страница 7: ...llierende Teile definiert und unter Pfad Sensor Sensor_Upload auf dem Vision Viewer CE abgespeichert werden USB Stick Dann k nnen diese vordefinierten Konfigurationss tze wenn das neue Teil gepr ft we...

Страница 8: ...tch o mit dem Netzwerk oder dem Sensor Anschlussschema M glichkeit 1 Abb 3 155 01104 FA 45 CE Viewer RJ45 M12 CI L4MGK RJ45G GS xm PUR CI L8FSK RJ45S xm GG PVC G FA 45 300 S3 FA 45 300 S4 FA 45 300 S5...

Страница 9: ...gefragt Das R cksetzen des Passworts falls dieses z B vergessen wurde erfolgt indem im file SensorFinder SensoFinder Config INI in der Rubrik Password die Werte nach User und Admin gel scht werden Abb...

Страница 10: ...resse des Vision Viewer CE F r die Verbindung des FA 45 Vision Sensors mit einem Computer via EtherNet m ssen die IP Adress Einstellungen der beiden Ger te korrespondieren Die Werkseinstellung des Vis...

Страница 11: ...inder startet Anwender Software Doppelklick auf Sensor in der Liste PC Software startet Sensor und Softwareversion pr fen Sensorversion wird im SensoFinder angezeigt z B 40 Kompatibilit tstabelle und...

Страница 12: ...E und ggf f r FA45 Sensor erfragen Zur Umstellung des Vision Viewer CE vorgehen wie unter Kap 2 2 1 Direkter Anschluss beschrieben Zur Umstellung des Sensors vorgehen wie im Kapitel 2 2 1 2 in der Mon...

Страница 13: ...hier im Speicher gel scht Abb 10 155 01109 Einst anz Fordert die aktuelle Einstellung des Rekorders vom Sensor an was mit einem Stop des Run Modes verbunden ist Der ermittelte Modus wird in der Combo...

Страница 14: ...sca auf den Sensor geladen werden Jede unter diesem Pfad abgepeicherte Konfiguration wird einzeln als Button auf der Oberfl che dargestellt Durch Bet tigen des Buttons wird der Upload der jeweiligen...

Страница 15: ...tions 16 1 3 Scope of delivery 16 2 Functional description 17 2 1 Data input on device 19 2 2 Network settings 22 2 2 1 Direct connection Setting Vision Viewer CE s IP address 22 2 2 2 1 Network conne...

Страница 16: ...information 1 2 Safety instructions These mounting and operating instructions in particular the safety instructions must be read understood and observed before installing the Vision Viewer CE The Visi...

Страница 17: ...FA45 VGA CCD mono object detection C CS mount lens high end Ethernet RS422 522 91054 FA45 300 CR V5 Code readers FA 45 300 WCC CRO6 HS6 FA45 Code reader high end 6 mm lens white light 4 pin Ethernet 5...

Страница 18: ...ader extended quality parameters C mount 4 pin Ethernet Ethernet IP 522 91163 FA 45 300 RCC CRO6 ES7 FA45 Code reader extended quality parameters 6 mm lens red light 4 pin Ethernet Ethernet IP 522 911...

Страница 19: ...ssible to define configuration sets for other parts to be inspected and save them on the CE Viewer USB memory stick under the path Sensor Sensor_Upload These predefined configuration sets can then be...

Страница 20: ...sing the supplied Ethernet cable Connection diagram Possibility 1 Fig 3 155 01104 FA 45 M12 CI L4MGK RJ45G GS xm PUR CI L8FSK RJ45S xm GG PVC G FA 45 300 S3 FA 45 300 S4 FA 45 300 S5 FA 45 300 S6 CE V...

Страница 21: ...ossible to reset the password should it e g be forgotten This is carried out in the SensorFinder SensoFinder Config INI file under the rubric password by deleting the User and Admin entries Fig 5 155...

Страница 22: ...the FA 45 Vision Sensor to a computer via Ethernet the IP address settings of both devices must correspond The IP address in the Vision Viewer CE has the factory setting 192 168 100 101 with subnet m...

Страница 23: ...n software Double click on sensor in the list PC application software starts Sensor and Softwareversion test Sensorversion is displayed in the SensoFinder e g 40 Table of compatibility and correspondi...

Страница 24: ...tings etc for Vision Viewer CE and if necessary for FA45 Sensor To change over the Vision Viewer proceed as described in chapter 2 2 1 Direct connection To change over the sensor proceed as described...

Страница 25: ...it without images having been stored they will also be deleted from the memory here Fig 10 155 01109 Get Mode Requests the current recorder setting from the sensor which involves interruption of run m...

Страница 26: ...an be loaded on to the sensor Each configuration stored under this path appears on the user interface as an individual button Activating the button triggers the uploading of the respective configurati...

Страница 27: ...1 3 D tail de la livraison 28 2 Description des fonctions 29 2 1 Saisies sur l appareil 31 2 2 R glages r seau 34 2 2 1 Raccordement direct R glage de l adresse IP du Viewer Vision CE 34 2 2 2 1 Racco...

Страница 28: ...e en marche de l unit de contr le IO lire comprendre et imp rativement respecter les instructions de montage et de fonctionnement particuli rement les informations de s curit Le raccordement de l unit...

Страница 29: ...ection d objets objectif CCS Mount Objektiv High End Ethernet RS422 522 91054 FA45 300 CR V5 Lecteurs de codes FA 45 300 WCC CRO6 HS6 FA45 lecteur de code Highend objectif 6 mm lumi re blanche 4 p les...

Страница 30: ...es qualit C Mount 4 p les Ethernet Ethernet IP 522 91163 FA 45 300 RCC CRO6 ES7 FA45 lecteur de code avanc param tres qualit objectif 6 mm lumi re rouge 4 p les Ethernet Ethernet IP 522 91164 FA 45 30...

Страница 31: ...on peut ici d finir des phrases de configuration pour contr ler ult rieurement des pi ces et les sauvegarder sous Sensor Sensor_Upload sur le Viewer CE Cl USB Il est ainsi possible lors du contr le de...

Страница 32: ...au ou par un commutateur le Viewer Sch ma de raccordement Cas 1 Illustr 3 155 01104 FA 45 M12 CI L4MGK RJ45G GS xm PUR CI L8FSK RJ45S xm GG PVC G FA 45 300 S3 FA 45 300 S4 FA 45 300 S5 FA 45 300 S6 CE...

Страница 33: ...mp mot de passe a t laiss vide ce mot de passe ne sera plus demand L annulation du mot de passe s il a t oubli s effectue dans le dossier SensorFinder SensoFinder Config INI dans la rubrique Mots de p...

Страница 34: ...IP du Viewer Vision CE Afin de raccorder le capteur de vision FA 45 avec un ordinateur via Ethernet les r galges de l adresse IP des deux appareils doivent correspondre Le r glage usine du Viewer Visi...

Страница 35: ...res demande de renseignement SensoFinder d marre t il le logiciel d utilisation double clic sur le capteur dans la liste Le logiciel PC d marre V rifier la version du capteur et du logiciel La version...

Страница 36: ...nce pour le capteur FA 45 Proc der pour la modification du Viewer Vision comme d crit au chapitre 2 2 1 Raccordement direct Proc der pour la modification du capteur comme d crit au chapitre 2 2 1 2 da...

Страница 37: ...les images seront supprim es de la m moire Illustr 10 155 01109 Afficher r glages Requiert le r glage actuel de l enregistreur en partant du capteur ce qui est li l arr t du mode run Le mode trouv est...

Страница 38: ...werCE exe seront charg es sur le capteur Chaque configuration sauvegard e sous ce chemin sera repr sent e par un bouton sur l interface On provoque le chargement de la dite configuration sur le capteu...

Страница 39: ......

Страница 40: ...instein Espace Mercure F 77420 Champs Marne la Vall e T l 33 0 1 64 73 00 61 Fax 33 0 1 64 73 10 87 info sensopart fr www sensopart fr Great Britain SensoPart UK ltd G8 The Arch 48 52 Floodgate Street...

Отзывы: