background image

Contact details:  SENSITRON s.r.l. 

Viale della Repubblica, 48 - 20007 - Cornaredo (MI) Italy

TEL. +39 0293548155 - FAX +39 0293548089 - www.sensitron.it  -  E-mail: [email protected]

LEADER IN SIL2 (SIL3) FIXED GAS DETECTION SYSTEMS

Sensitron has a policy of continuous development and improvement of its products. As such the specifica-
tion for the device outlined in this document may be changed without notice. In case of modification of the 
product, Sensitron disclaims all liability. Data may change, as well as legislation and you are strongly advised to 
obtain copies of the most recently issued regulations, standards and guidelines. This publication is not inten-
ded to form the basis of a contract. No part of this publication may be reproduced, distributed, or transmitted 
in any form or by any means, including photocopying, recording, or other electronic or mechanical methods, 
without the prior written permission of Sensitron. 

6.  Instructions for disposal

When the device reaches the end of its life, it should be disposed of in accordance with local 

waste management requirements and environmental legislation.

Employed materials are subdivided into the following categories:

 

³

Remote terminal unit enclosure: Plastic

 

³

Base board: Waste Electrical & Electronic Equipment (WEEE)

Alternatively, the old device may be securely packaged, clearly marked for environmental 

disposal and returned to Sensitron.

Содержание STG/IN8-S2

Страница 1: ...Manuale d istruzione Instruction Manual MT4977 R1 24 11 2021 2021 SENSITRON S R L All rights reserved www sensitron it Modulo ingressi Input module STG IN8 S2...

Страница 2: ...for any additional information relative to use or repair QUESTO MANUALE DEVE ESSERE LETTO ATTENTAMENTE DATUTTI COLORO CHE HANNO O AVRANNO LA RESPONSABILITA DI INSTALLARE UTILIZZARE O DI PRESTARE UN S...

Страница 3: ...ayout 5 3 Addressing 5 4 Detector connections 7 5 Module dimensions 7 6 Instructions for disposal 8 SOMMARIO 1 Introduzione 1 2 Topografico modulo 1 3 Indirizzamento 1 4 Collegamento rilevatori 3 5 Di...

Страница 4: ...i 0 F ed il puntatore viene posizionato sul numero scelto tramite un cacciavite a formare un valore decimale da 1 a 255 vedi tabella Per il numero massimo di moduli che possibile collegare far riferim...

Страница 5: ...122 7A 159 9F 196 C4 233 E9 12 0C 49 31 86 56 123 7B 160 A0 197 C5 234 EA 13 0D 50 32 87 57 124 7C 161 A1 198 C6 235 EB 14 0E 51 33 88 58 125 7D 162 A2 199 C7 236 EC 15 0F 52 34 89 59 126 7E 163 A3 20...

Страница 6: ...6D 146 92 183 B7 220 DC 36 24 73 49 110 6E 147 93 184 B8 221 DD 37 25 74 4A 111 6F 148 94 185 B9 222 DE 4 Collegamento rilevatori Figura 3 Collegamento rilevatori 5 Dimensioni modulo Figura 4 Dimensi...

Страница 7: ...ere riprodotta distribuita o trasmessa in qualsiasi forma o con qualsiasi mezzo inclusi fotocopie registrazioni o altri metodi elettronici o meccanici senza la previa autorizzazione scritta di Sensitr...

Страница 8: ...d using the rotary switches on the PCB The address must be univocal and between 1 and 255 In any case please refer to the control panel manual for the appropriate module using and setting 2 Module lay...

Страница 9: ...120 78 157 9D 194 C2 231 E7 10 0A 47 2F 84 54 121 79 158 9E 195 C3 232 E8 11 0B 48 30 85 55 122 7A 159 9F 196 C4 233 E9 12 0C 49 31 86 56 123 7B 160 A0 197 C5 234 EA 13 0D 50 32 87 57 124 7C 161 A1 1...

Страница 10: ...B6 219 DB 35 23 72 48 109 6D 146 92 183 B7 220 DC 36 24 73 49 110 6E 147 93 184 B8 221 DD 37 25 74 4A 111 6F 148 94 185 B9 222 DE 4 Detector connections Figure 3 Detector connections 5 Module dimensio...

Страница 11: ...ons standards and guidelines This publication is not inten ded to form the basis of a contract No part of this publication may be reproduced distributed or transmitted in any form or by any means incl...

Отзывы: