Main Menu Screen 

The

 

Main

 

Menu

 

Screen

 

provides

 

an

 

overview

 

of

 

the

 

system

 

(Serial

 

#,

 

Software

 

Rev#,

 

Date

 

and

 

Time,

 

Valve

 

Configuration).

 

It

 

also

 

provides

 

access

 

to

 

view

 

calibration

 

gas

 

information,

 

view

 

logs,

 

update

 

settings

 

through

 

the

 

Supervisor

 

Menu,

 

and

 

a

 

Test

 

Menu.

 

The

 

Valve

 

Setup

 

Overview

 

provides

 

information

 

about

 

which

 

gas

 

inlets

 

(valves)

 

are

 

configured

 

for

 

each

 

calibration

 

gas.

 

Each

 

lure

 

inlet

 

on

 

the

 

manifold

 

is

 

color

 

coded

 

with

 

label

 

around

 

it.

 

 

The

 

Supervisor

 

and

 

Test

 

Menu

 

screens

 

are

 

password

 

protected.

 

 

 

 

 

 

 

 

 

 

 

Calibration Gas Information Screen 

This

 

screen

 

is

 

divided

 

in

 

eight

 

cells.

 

Each

 

cell

 

represents

 

a

 

single

 

gas

 

inlet

 

(valve).

 

The

 

background

 

colors

 

and

 

gas

 

inlets

 

are

 

color

 

coded

 

and

 

matched

 

for

 

easy

 

identification.

 

The

 

colors

 

on

 

the

 

manifold

 

label

 

correspond

 

to

 

the

 

colors

 

shown

 

on

 

this

 

screen.

 

It

 

also

 

provides

 

the

 

information

 

about

 

type

 

of

 

regulator

 

required

 

for

 

the

 

gas

 

bottle

 

and

 

the

 

expiration

 

date

 

of

 

the

 

calibration

 

gas.

 

A

 

blank/empty

 

cell

 

indicates

 

that

 

particular

 

gas

 

inlet

 

(valve)

 

is

 

not

 

configured

 

and

 

will

 

not

 

be

 

used.

 

N/A

 

in

 

a

 

cell

 

indicates

 

that

 

the

 

valve

 

is

 

not

 

installed.

 

Tapping

 

on

 

a

 

configured

 

cell

 

(i.e.

 ‐ 

not

 

blank/empty)

 

will

 

take

 

you

 

the

 

password

 

screen.

 

Upon

 

providing

 

the

 

correct

 

password,

 

the

 

calibration

 

gas

 

information

 

will

 

be

 

displayed.

 

   

 

 

 

 

 

 

 

Sample

 

image

 

of

 

the

 

Main

 

Screen:

 

 

Sample

 

image

 

of

 

the

 

Calibration

 

Gas

 

Information

 

Screen:

 

Содержание SCAL-400

Страница 1: ...N D E R S T A N D I N S T R U C T I O N S B E F O R E U S E FOR USE IN AREAS KNOWN TO BE FREE OF COMBUSTIBLE GAS HAZARDS FOR USE IN AREAS THAT ARE CLEAN AND DRY 851 Transport Drive Valparaiso IN 4638...

Страница 2: ......

Страница 3: ...en 7 Main Menu Screen 8 Calibration Gas Information Screen 8 Log Review Screen 9 Password Screen 9 Supervisor Menu Screen 10 12 Operation Set up 13 Operation System Activation 13 Operation P400 Testin...

Страница 4: ...emperature 40 122 F 5 50 C Maximum inlet pressure 20psi Features Touch screen display LED status indicators Charging pins Communication pin Power connection RJ45 Serial Connections Cooling fan intake...

Страница 5: ...t is referred to as a slot For each slot there are charger and communication connections as well as LEDs to indicate the status All testing functions require no user interaction The display is a touch...

Страница 6: ...Screen only if no unit test is pending or in progress Sample image of the Main Screen Table 1 Main Screen background colors and descriptions Slot Screen Background color Status Description GRAY Empty...

Страница 7: ...ttery WHITE CHARGING RED ALKALINE LOW BATTERY GREEN CHARGED ALKALINE OK 3 Data Transfer GRAY PENDING WHITE UPDATING RTC DOWNLOADING CALIBRATION LOG DOWNLOADING BUMP TEST LOG GREEN COMPLETED DATA TRANS...

Страница 8: ...eight cells Each cell represents a single gas inlet valve The background colors and gas inlets are color coded and matched for easy identification The colors on the manifold label correspond to the co...

Страница 9: ...omatically be checked Upon providing the correct password the next screen will be displayed Entering an incorrect password will change the screen title to be displayed as WRONG PASSWORD in red After t...

Страница 10: ...SCal 400 application All available time zones will be listed Select the appropriate time zone and click UPDATE A message box will be displayed to indicate system will restart Click OK to continue 2 S...

Страница 11: ...be present A copy of the database will be saved to the memory card every day The automatically saved backup files are named AUTO_DDMMYYYY sdf b BACKUP DATABASE This option will create a manual backup...

Страница 12: ...libration bump test 12 PURGE TIME AFTER Amount of time in seconds the unit will purge the line with air after it completes a calibration bump test 13 SPECIALITY GAS PURGE Amount of time in seconds the...

Страница 13: ...ot 4 If the instrument is off it will turn on automatically 5 The instrument will be bump tested and or calibrated as determined by the instrument setup 6 The instrument will recharge if needed Alkali...

Страница 14: ...NOTES...

Страница 15: ...NOTES...

Страница 16: ...before warranty is rendered Units out of warranty will be repaired for a service charge Internal repair or maintenance must be performed by a Sensit Technologies authorized technician Violation will...

Отзывы: