Specifications 

Power:

 

100

 

 

240

 

VAC

 

input

 

Size:

 

24”

 

X

 

7”

 

X

 

3”

 

(61cm

 

X

 

17.8cm

 

X

 

7.6cm)

 

Weight:

 

5.75

 

lbs.

 

(2.6

 

kg)

 

Operational

 

Temperature:

 

40

 ‐ 

122°F

 

(5

 ‐ 

50°C)

 

Maximum

 

inlet

 

pressure:

 

20psi

 

 

Features 

Touch

 

screen

 

display

   

LED

 

status

 

indicators

   

Charging

 

pins

 

 

Communication

 

pin

 

 

                         

Power

 

connection

   

                 

RJ45

     

Serial

   

 

 

 

 

 

 

 

       

Connections

 

     

 

Cooling

 

fan

 

intake

 

 

 

 

 

Gas

 

inlets/connections

 

 

 

 

4

What’s Included:

SCAL-400

Power Cord (120 VAC)

Instruction Manual

SCAL-D Software

USB Cable

Содержание SCAL-400

Страница 1: ...N D E R S T A N D I N S T R U C T I O N S B E F O R E U S E FOR USE IN AREAS KNOWN TO BE FREE OF COMBUSTIBLE GAS HAZARDS FOR USE IN AREAS THAT ARE CLEAN AND DRY 851 Transport Drive Valparaiso IN 4638...

Страница 2: ......

Страница 3: ...en 7 Main Menu Screen 8 Calibration Gas Information Screen 8 Log Review Screen 9 Password Screen 9 Supervisor Menu Screen 10 12 Operation Set up 13 Operation System Activation 13 Operation P400 Testin...

Страница 4: ...emperature 40 122 F 5 50 C Maximum inlet pressure 20psi Features Touch screen display LED status indicators Charging pins Communication pin Power connection RJ45 Serial Connections Cooling fan intake...

Страница 5: ...t is referred to as a slot For each slot there are charger and communication connections as well as LEDs to indicate the status All testing functions require no user interaction The display is a touch...

Страница 6: ...Screen only if no unit test is pending or in progress Sample image of the Main Screen Table 1 Main Screen background colors and descriptions Slot Screen Background color Status Description GRAY Empty...

Страница 7: ...ttery WHITE CHARGING RED ALKALINE LOW BATTERY GREEN CHARGED ALKALINE OK 3 Data Transfer GRAY PENDING WHITE UPDATING RTC DOWNLOADING CALIBRATION LOG DOWNLOADING BUMP TEST LOG GREEN COMPLETED DATA TRANS...

Страница 8: ...eight cells Each cell represents a single gas inlet valve The background colors and gas inlets are color coded and matched for easy identification The colors on the manifold label correspond to the co...

Страница 9: ...omatically be checked Upon providing the correct password the next screen will be displayed Entering an incorrect password will change the screen title to be displayed as WRONG PASSWORD in red After t...

Страница 10: ...SCal 400 application All available time zones will be listed Select the appropriate time zone and click UPDATE A message box will be displayed to indicate system will restart Click OK to continue 2 S...

Страница 11: ...be present A copy of the database will be saved to the memory card every day The automatically saved backup files are named AUTO_DDMMYYYY sdf b BACKUP DATABASE This option will create a manual backup...

Страница 12: ...libration bump test 12 PURGE TIME AFTER Amount of time in seconds the unit will purge the line with air after it completes a calibration bump test 13 SPECIALITY GAS PURGE Amount of time in seconds the...

Страница 13: ...ot 4 If the instrument is off it will turn on automatically 5 The instrument will be bump tested and or calibrated as determined by the instrument setup 6 The instrument will recharge if needed Alkali...

Страница 14: ...NOTES...

Страница 15: ...NOTES...

Страница 16: ...before warranty is rendered Units out of warranty will be repaired for a service charge Internal repair or maintenance must be performed by a Sensit Technologies authorized technician Violation will...