This power supply unit meets the essential requirements of the  
following EU Directives: 
 

 

 
 
 
 

 

Functional standard:     

EN54-4:1997 +A1 +A2 

    

Environmental Class II  

 

Certification Body:       

Underwriters Laboratory 

 
Declaration of Performance: 

DOP2014/06 

  

 

DOP2014/07

 

 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

 

 
This product falls within the scope of EU Directives 2012/19/EU Waste Electrical and Electronic Equipment 
(WEEE)  and  2013/56/EU  (Battery).  At  the  end  of  life,  the  product  must  be  separated  from  the  domestic 
waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national 
and local regulations. 
Before disposal of the product, any batteries must be removed, and disposed separately via an appropriate 
approved battery disposal route in accordance with all national and local regulations. Package used batteries 
safely for onward transport to your supplier, collection point or disposal facility. 
 

Caution:  Risk of fire or explosion  

if bare battery wires are allowed to touch. 

 
See  Specification  for  battery  type  information.  The  battery  is  marked  with  the  crossed  out  wheelie  bin 
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). 
 

For more information see: 

www.recyclethis.info

 

 
 
 
 
 
 
 
 
 
 

The packaging supplied with this product may be recycled. 

 Please dispose of packaging accordingly. 

CPR: 

305/2011 EU 

EMC: 

2014/30/EU

 

Low Voltage: 

2014/35/EU 

WEEE: 

2012/19/EU 

RoHS: 

2011/65/EU 

0843 

 

Elmdene International Ltd 3 Keel Close 

Portsmouth PO35QD 

14 

0843-CPR-0215 

EN54-4:1997 +A1 +A2 

Power Supplies intended for use in fire detection 

and fire alarm systems 

 

Operational reliability

                    - Pass 

 

Durability 

 

 

 

Temperature resistance  

- Pass 

Vibration resistance 

- Pass 

Electrical stability 

- Pass 

Humidity resistance 

- Pass 

 
 

Содержание V02205

Страница 1: ...olid state relay fault output signal i loss of mains and ii battery fault charger fault and loss of output In addition there is an optional plug in serial interface that can provide diagnostic and fault reporting information to supervisory systems Certified by UL to EN54 4 1997 A1 A2 Up to 5A current to load at 27 6V dc nominal regulated output Charging capability to support 7 or 17 18Ah batteries...

Страница 2: ...l Yuasa model Interlogix model 2 x 2 1 Ah 12 V PS12021 NP2 1 12 2 x 7 Ah 12 V PS12070 NP7 12 2 x 17 18 Ah 12 V PS12170 NP17 12 BS131N Battery Charging Constant current bulk charging to 80 capacity within 24 hours Float charging to 100 within 48 hours Eco charging and check every 24 hours for up to 8 hours pulse charge dependent on temperature Constant current charge 0 8 A Low battery threshold vol...

Страница 3: ...ction CLOSED CLOSED Normal operation Mains present Battery healthy None No fault OPEN CLOSED Standby Mode Mains lost Battery driving load Investigate loss of mains CLOSED OPEN Fault Present Blown fuses Battery fault Internal fault Investigate fault source using diagnostic LED Rectify fault where possible OPEN OPEN PSU Shutdown Mains lost Standby battery exhausted Restore mains as soon as possible ...

Страница 4: ...ire detection and fire alarm systems If the PSE is used as a power supply for Control and Indicating Equipment CIE the PSE shall be installed no further than 10cm from the CIE and close coupled by conduit This unit must be fed from a mains power source having a separate approved disconnect device and fitted with a fuse or other over current protection device rated at 5 A maximum Ensure that the di...

Страница 5: ... Ah batteries and as such weighs 18 5 Kg when loaded Ensure that wall fixings are appropriate to support this weight The product should be mounted no further than 10 cm from the control and indicating equipment close coupled by conduit if it is being used to power the CIE directly 7 Fix to wall or other structure in correct orientation i e with hinge on left hand side using screws of sufficient si...

Страница 6: ... approximately 3 s indicating a disconnected battery 3 Disconnect the mains power Load Output and Remote Signalling 4 Connect the EPS and GEN PSE Fault outputs to the appropriate inputs of control equipment if remote fault monitoring is required 5 Loop the load output wiring through the supplied ferrite EMC suppressor Cable tie to saddle provided adjacent to exit hole Figure 3 Connections 6 Re app...

Страница 7: ...a closed contact and the GEN PSU Fault monitor shows a closed contact 18 Disconnect one of the battery leads ensuring that no exposed section of conductor or connector is allowed to contact exposed metal work other PSE terminals or other battery terminals 19 Verify that in less than 10 s the yellow Fault LED starts to flash and that the orange Diagnostic LED flashes in a 2 pulse repeating pattern ...

Страница 8: ...ate approved battery disposal route in accordance with all national and local regulations Package used batteries safely for onward transport to your supplier collection point or disposal facility Caution Risk of fire or explosion if bare battery wires are allowed to touch See Specification for battery type information The battery is marked with the crossed out wheelie bin symbol which may include ...

Отзывы: