![Sensear smartPlug Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/sensear/smartplug/smartplug_manual_1243370023.webp)
DOC00071 smartPlug™ Manual rev 02
21
PASSIVE ATTENUATION (ANSI S12.6 – 2008)
smartPlug™ measured in accordance with ANSI S12.6–2008 (Method B)
Foam tips (SML, MED, LRG)
Frequency (Hz)
125
250
500
100
2000
4000
8000
NRS
Mean
attenuation(dB)
32.0
29.2
32.3
32.0
37.0
40.8
42.6
29 to 39dB
Standard
deviation
(dB)
6.1
6.5
6.8
6.7
5.1
5.8
4.5
APV84%
26.9
23.7
26.6
26.0
32.7
35.9
38.8
PASSIVE ATTENUATION (AS/NZS 1270:2002)
smartPlug™ measured in accordance with AS/NZS1270:2002.
Foam tips (SML, MED, LRG)
Frequency (Hz)
125
250
500
1000
2000
4000
8000
SLC(80)
Mean
attenuation(dB)
31.7
28.1
32.1
32.7
36.7
39.5
42.0
28dB,
Class5
Standard deviation
(dB)
9.7
7.8
8.0
8.2
5.7
7.6
5.7
Mean attenuation–
Standard deviation
(dB)
22.0
20.3
24.1
24.5
31.0
31.9
36.3