Document 

IMA0215

  

Rev 

7

 

Page 
4 (8)

 

 

Electrical connections

 

 

 

The power supply 

has to be connected

 

to 

 

and 

 is considered as system 

ground. 

The same ground reference has to be used for

 

the eSENSE unit and for the 

DDC/signal receiver.

   

 

PLEASE NOTE! 
The same ground reference has to be used for the 

eSENSE

 

unit and for the control system!

 

 

Terminal 

Function 

Electrical data 

Remarks 

Standard 

settings 

Remarks 

Settings of 

this sensor 

 

 

 

Power (+) 

 
 

Power ground 

(-) 

24 VAC/DC+  (+-

20%), 2W 

 

24 VAC/DC- 

 
 
 
System voltage 
reference 

 

Out(1) 

 
 

Out(2) 

 

Analogue 

output 1 (+) 

 

Analogue 

output 2 (+) 

 

0-10 VDC or 

According to label 

 

2,0…10,0 VDC or  

4,0 … 20,0 mA or 

According to label 

 

0,9…1,6 VDC or 

1.5 to 2,5 mA 

 

0 VDC or 0mA 

0-2000 ppm

 

CO

2

 

 
 
0-2000 ppm

 

CO

 
 
 
Status = ERROR 
 
 
Status = NOT 
READY 

 

Table I. Connections of the main terminal of eSENSE  

 

~

+

~

+

Содержание eSENSE Duct-TR

Страница 1: ...the measured CO2 value in ppm parts per million on the LCD The units are designed for connecting to Direct Digital Control DDC with 0 10V or 2 10V signal inputs The two parallel signal outputs Out 1...

Страница 2: ...9 8 1 Sampling probe 6 O ring 29 2x3 53 2 Sealing gasket 7 PCB Factory supplied mounted in box 3 Largest locking nob 8 Snap in lid 4 2 washers Not included 9 Cable entry bushing 5 2 screws Not includ...

Страница 3: ...ctrical cable entry The box has a factory mounted cable entry bushing Never feed more than one cable through each cable entry bushing or else gas might leak through 3 Mounting the tube Drill a hole 10...

Страница 4: ...eSENSE unit and for the control system Terminal Function Electrical data Remarks Standard settings Remarks Settings of this sensor Power Power ground 24 VAC DC 20 2W 24 VAC DC System voltage referenc...

Страница 5: ...with the jumper set to voltage output right position Self diagnostics The system contains a complete self diagnostic procedure that is executed automatically when the sensor is in operation Sensors w...

Страница 6: ...uilt in self correcting ABC algorithm Discuss your application with SenseAir in order to get advice for a proper calibration strategy PLEASE NOTE The sensor accuracy is defined at continuous operation...

Страница 7: ...Document IMA0215 Rev 7 Page 7 8 Dimensions Figure 7 The dimensions of the sensor in mm and inches...

Страница 8: ...marking Directive 93 68 EEC The product fulfils the following demands EN 61000 4 2 level 2 EN 61000 4 3 level 2 EN 61000 4 4 level 4 EN 61000 4 6 EN 61000 4 8 level 4 EN 55022 class B SenseAir AB head...

Отзывы: