Page 31
12NP Manual
Configurations
Configurations
Table 8 Setting Options
Table 9 Battery Charger Customization Options
Table 10 LFP Setting Options
*The LCD converts temperature settings into a Celsius integer before transmitting to the inverter. Setting changes
of only 1°F on the LCD may not always change the setpoint within the inverter. Changes of 2°F will change the
setpoint within the inverter.
0.1C charging is the feature in which the charger will reduce the charge current to ten percent of the amp hour
rating. See the specification table for the default amp hour setting. The amp hour setting may be adjusted with CAN
or the optional LCD remote.
Settings
Battery Type
Wet
AGM
Gel
LFP
Battery Profile
1
1
1
See Table 10
Default CV
14.6 VDC
14.5 VDC
14.1 VDC
14.4 VDC
Min CV
12.0 VDC
12.0 VDC
12.0 VDC
13.9 VDC
Max CV
15.4 VDC
15.3 VDC
14.9 VDC
14.8 VDC
Default CV Timer
6.0 hrs
6.0 hrs
6.0 hrs
0.5 hrs
Min CV Timer
0.5 hrs
0.5 hrs
0.5 hrs
0.5 hrs
Max CV Timer
25.0 hrs
25.0 hrs
25.0 hrs
25.0 hrs
Default Float V
13.4 VDC
13.5 VDC
13.6 VDC
13.6 VDC
Min Float V
12.0 VDC
12.0 VDC
12.0 VDC
13.3 VDC
Max Float V
14.2 VDC
14.3 VDC
14.4 VDC
13.8 VDC
Battery Type
Profile
High Temp
Shutdown*
Cold Temp
Shutdown*
Cold Reduced
Charge*
LFP
1
45°C/113°F
0°C/32°F
5°C/41°F
LFP
2
45°C/113°F
None
5°C/41°F
LFP
3
60°C/140°F
0°C/32°F
5°C/41°F
LFP
4
60°C/140°F
None
5°C/41°F
Options
Increment
Default
Low Batt
10.0 V
to
13.0 V
.1 V
10.5 V (11.5 V for LFP)
BCR
5 A
to
30 A
5 A
15 A
AC Line Qualify
5 secs
to
30 secs
5 secs
30 secs
CAN Instance
1
to
13
1
1
Baud Rate
250k
or
500k
N/A
250k