K.4 Statuses of device are shown in table K.2
Table K.2
Value
Description
0x80
Device failure. Device has detected hardware error or error.
0x40
Configuration was changed. Command for change or writing of device
parameter was executed.
0x20
Cold start. Power supply failure or device reset occurred.
0x08
Fixed current in a loop. Current in loop is fixed at required value and does not
reflect change of primary variable.
0x04
Saturation of current loop. Value of current in loop has reached its upper (or
lower) threshold and cannot increase (or decrease) more.
K.5 Data types are shown in table K.3
Table K.3
Type designation
Type description
u-8, u-16, u-24, etc.
Integer unsigned, with specified number of bits
float
Floating-point format (4 bytes, IEEE 754 format)
enum
Enumeration
bits
Sequence of bits (flags)
ascii
Packed ASCII string, with 4 characters packed in each 3 bytes
date
3 three bytes of date (date, month, year - 1900)
latin
ISO Latin-1 (ISO 8859-1)
K.6 Read/write functions restriction is shown in table K.4.
Hereinafter following designations are used:
R - read-only;
RS - read/write;
P - "User" access level;
A - "Administrator" access level (parameter change);
B - possibility to lock from accidental change.