background image

Using the plug-on transmitter

Using the plug-on transmitter

To establish a transmission link, proceed as follows:

1. Switch the diversity receiver on (see the instruction manual of the

receiver).

2. Switch the plug-on transmitter on (see below).

The transmission link is established and the diversity receiver’s RF level
display “

RF

” reacts.

Switching the plug-on transmitter on/off

To switch the plug-on transmitter 

on 

(online operation):

To switch the plug-on transmitter 

off

:

If necessary, deactivate the lock mode (see page 9).

To switch the plug-on transmitter 

on

 and to 

deactivate the RF signal on

switch-on

 (offline operation):

To 

activate

 the 

RF signal

:

Press the

 ON

/

OFF 

button

.

The plug-on transmitter transmits an RF signal. The red

ON

LED

 lights up and the standard display “

Frequency/

Name

” appears on the display panel. The transmission icon

is displayed.

You can switch the plug-on transmitter on and deactivate the
RF signal on switch-on. For more information, see below.

Press the 

ON

/

OFF

button 

 until “

OFF

” appears on the

display panel. 
The red 

ON

LED 

 goes off and the display panel turns off.

When in the operating menu, pressing the 

ON

/

OFF

button

 will

cancel your entry (ESC function) and return you to the current
standard display.

Press the 

SET

button until “

RF Mute On?

” appears on the

display panel.

Press the 

SET

button.

The transmission frequency is displayed but the plug-on
transmitter does not transmit an RF signal. The transmission
icon

 is not displayed.

Use this function to save battery power or to prepare a plug-on
transmitter for use during live operation without causing inter-
ference to existing transmission links.

Press the

 ON

/

OFF 

button.

RF Mute Off

” appears on the display panel.

Press the 

SET

button. 

The transmission icon

 is displayed again.


ON/OFF

ON/OFF

SET

SET

MHz

533.875

ew100 G3

MUTE

P

AF

ON/OFF

SET

Содержание SKP 100 G3

Страница 1: ...Instruction Manual SKP 100...

Страница 2: ...vating the lock mode temporarily 9 Muting the audio signal or deactivating the RF signal 9 Selecting a standard display 10 Using the operating menu 11 The buttons 11 Overview of the operating menu 11...

Страница 3: ...titutions may result in fire electric shock or other hazards Refer all servicing to qualified service personnel Servicing is required if the device has been damaged in any way liquid has been spilled...

Страница 4: ...ady for immediate use after switch on several transmission systems can be operated simultaneously on the preset frequencies without causing intermodulation interference The frequency bank system The p...

Страница 5: ...informa tion sheet can be downloaded from the SKP 100 G3 product page on our website at www sennheiser com The frequency bank U allows you to freely select and store transmission frequencies It might...

Страница 6: ...le unbalanced Mechanical locking ring of XLR 3 socket Infra red interface Display panel backlit in orange UP button DOWN button Operation and battery status indicator red LED lit ON flashing LOW BATTE...

Страница 7: ...econds Display Meaning Audio level AF Modulation of the plug on transmitter with peak hold function Frequency Current transmission frequency Name User selectable name Transmission icon RF signal is be...

Страница 8: ...nt The battery compartment cover locks into place with an audible click Charging the accupack Remove the BA 2015 accupack optional accessory Insert the BA 2015 accupack into the L 2015 charger accupac...

Страница 9: ...panel The transmission icon is displayed You can switch the plug on transmitter on and deactivate the RF signal on switch on For more information see below Press the ON OFF button until OFF appears o...

Страница 10: ...h to the left to the position MUTE The plug on transmitter reacts as indicated in the table Press the ON OFF button Locked appears on the display panel Press the UP button Unlock appears on the displa...

Страница 11: ...Transmitter s display panel Transmission icon is displayed MUTE is not displayed You can also deactivate the RF signal on switch on For more infor mation refer to the chapter Switching the plug on tra...

Страница 12: ...the frequency bank and the channel 13 Name Enters the transmitter name 14 Auto Lock Activates deactivates the automatic lock mode 14 Advanced Calls up the extended menu Advanced Menu 14 Exit Exits the...

Страница 13: ...last selected menu item is displayed Press the UP button DOWN button to change to the Sensitivity menu item The current setting of the selected menu item is displayed Press the SET button to call up t...

Страница 14: ...oo high Close talking distances speakers with loud voices or loud music passages cause overmodulation in the trans mission link The audio level display AF shows full deflection for the duration of the...

Страница 15: ...use the lock mode refer to page 9 The extended menu Advanced Menu Setting transmission frequencies and the frequency bank U Tune When you have selected one of the system banks and then select the Tune...

Страница 16: ...il the frequency bank selec tion appears Press the SET button The frequency selection appears Mode Function AF On Off When the switch is in the MUTE position no audio signal is transmitted RF On Off W...

Страница 17: ...in 16 steps Loading the factory preset default settings Reset When resetting the plug on transmitter only the selected settings for the pilot tone and for the frequency bank U remain unchanged For an...

Страница 18: ...ation on automatic synchronization of the plug on transmitter with the receiver individual operation refer to the instruction manual of the receiver This information is marked with the icon Alternativ...

Страница 19: ...rge extent on location and can vary from about 10 m to about 150 m There should be a free line of sight between plug on transmitter and receiving antennas To avoid overloading the receiver observe a m...

Страница 20: ...on trans mitter to the same channel as the receiver Synchronize the plug on transmitter with the receiver see page 17 Transmissionrange is exceeded Reduce the distance between plug on trans mitter and...

Страница 21: ...0 Accessories Accessories The following SKP 100 G3 accessories are available from your specialist dealer Cat No Accessory 009950 BA 2015 accupack 009828 L 2015 charger 005232 POP 1 pouch with belt cli...

Страница 22: ...an be switched off Compander system Sennheiser HDX AF frequency response 80 18 000 Hz Signal to noise ratio 1 mV RF peak deviation 110 dBA THD 0 9 Max input voltage 3 3 Vrms Input impedance 60 k unbal...

Страница 23: ...e received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rule...

Страница 24: ...Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Printed in Germany Publ 01 09 529675 A01...

Отзывы: