background image

Specifications

20 | 

SK 9000 

Operating conditions

Storage and transport conditions

SK 9000 characteristics

RF characteristics

Latency

Analog Audio Out: 3.2 ms 

 

Digital Audio Out:  3 ms (AES/EBU)

THD

HD

” mode: < 0.01% (at 1 kHz) 

 

LR

” mode: < 0.03% (at 1 kHz) 

Ambient temperature

–10°C to +50°C

Relative humidity

max. 85% at 40°C 

 

(non-condensing)

Protection against 
dripping and light 
splashing of liquids

the product must not be exposed to 
dripping and splashing (IP2X)

Ambient temperature

–25°C to +70°C

Relative humidity

max. 90% at 40°C

Protection against 
dripping and light 
splashing of liquids

the product must not be exposed to 
dripping and splashing (IP2X)

Shock resistance

as per IEC 68 or EN 60068, T2-27

Frequency ranges

470 MHz to 798 MHz, 

 

divided into 4 ranges:

 

SK 9000 A1–A4:

470–558 MHz

SK 9000 A5–A8:

550–638 MHz

SK 9000 B1–B4:

630–718 MHz

SK 9000 B5–B8:

710–798 MHz

(see also table “System characteristics” 
on page 19)

Frequency ranges USA

550 MHz to 718 MHz, 

divided into 2 ranges:

SK 9000 A5–A8:

550–638 MHz

SK 9000 B1–B4:

630–718 MHz

Switching bandwidth

88 MHz

Содержание SK 9000

Страница 1: ...Instruction manual SK 9000...

Страница 2: ...adapter 9 Using the SK 9000 10 Switching the SK 9000 on off 10 Activating deactivating the automatic lock mode Autolock 12 Basic functions of the Sennheiser operating menu 13 Overview of the status di...

Страница 3: ...as been dropped WARNING To reduce the risk of fire or electric shock do not expose the product to rain or moisture Do not expose the product to dripping or splashing Intended use Intended use of the D...

Страница 4: ...ucts off after use Immediately remove rechargeable batteries from an obviously defective product When not using rechargeable batteries for extended periods of time charge them regularly about every th...

Страница 5: ...size alkaline batteries or 3 AA size lithium batteries Automatic detection of the input signal type mic line instru ment when Sennheiser accessories are used Emulation of different guitar cable lengt...

Страница 6: ...gularly remaining operating time is less than 30 minutes flashes with high levels audio signal is excessively high 4 Antenna socket 5 Infra red interface 6 DOWN button 7 SET button 8 UP button 9 Catch...

Страница 7: ...the BA 61 accupack the B 61 battery pack for three 1 5 V AA size batteries 1 Display for charge status of the accupack battery pack 2 Operating time display only when used with the BA 61 3 Frequency...

Страница 8: ...or the accupack battery pack If you touch the following contacts they can become dirty or damaged Contacts for supply voltage and data contacts B of the bodypack transmitter Charging and data contact...

Страница 9: ...shown in diagram 2 To attach the accupack battery pack Slide the accupack battery pack onto the guide rails A see diagram 1 until it locks into place with an audible click The bodypack transmitter is...

Страница 10: ...e the supplied antenna Connect the antenna as shown Connecting the KA 9000 COM command adapter Connect the 3 pin special audio connector of the KA 9000 COM to the 3 pin special audio socket 1 of the S...

Страница 11: ...ttery pack when the transmitter will not be used for extended periods of time see page 8 Before using your bodypack transmitter ask the relevant wireless regulatory authority for the exact frequency a...

Страница 12: ...ay HD LR flashes If you call up the Tune or Preset menu item within the next 10 seconds the RF signal remains deactivated until you exit the menu item If you do not call up one of the mentioned menu i...

Страница 13: ...e the automatic lock mode If however you try to call up any other menu item the fol lowing display appears on the display panel While this display is shown about 2 seconds you can temporarily deactiva...

Страница 14: ...l up the operating menu or a menu item to switch between the selection areas of a menu item and to store your settings Press the UP button DOWN button to select menu items and to change the settings o...

Страница 15: ...s the input gain 15 Low cut Sets the low cut filter 16 RF mode Adjusts the transmission mode 16 Display Selects a standard display 16 Cable Emulates different instrument cable lengths 16 Lock Activate...

Страница 16: ...of up to 6 char acters from the following character set Gain Adjusting the input gain Via the Gain menu item you can adjust the input gain in 3 dB steps from 6 to 42 dB To activate a different booster...

Страница 17: ...emulate the lengths of instru ment cables in 3 steps You can use this function when you are using the Sennheiser CI 1 4 line instrument cable Lock Activating deactivating the lock mode Via the Lock m...

Страница 18: ...and maintaining the SK 9000 Remove the rechargeable batteries or batteries before cleaning Only use a soft dry cloth to clean the bodypack transmitter Wipe the contacts B with a dry cloth CAUTION Liqu...

Страница 19: ...y panel Lock mode is activated Deactivate the lock mode No operation indication Batteries are flat or accupack is flat Replace the batteries or recharge the accupack see page 8 No RF signal at the rec...

Страница 20: ...kHz 3 dB with SK 9000 mic Dynamic range HD mode 112 dB A LR mode 101 dB A EM 9046 DRX TX variant Booster variant A1 A8 470 798 MHz expandable to 934 MHz A1 A4 470 558 MHz A1 470 494 MHz A2 494 518 MHz...

Страница 21: ...ping and splashing IP2X Ambient temperature 25 C to 70 C Relative humidity max 90 at 40 C Protection against dripping and light splashing of liquids the product must not be exposed to dripping and spl...

Страница 22: ...om 0 dB to 42 dB instruments adjustable in 3 dB steps from 6 dB to 9 dB line 6 dB Input impedance mic 22 k instruments line 1 M Lower cut off frequency 3 dB mic adjustable 60 Hz 80 Hz 100 Hz 120 Hz in...

Страница 23: ...adio EN 300422 1 2 Safety EN 60065 EN 62311 SAR USA Part 74 FCC ID DMOSK9000 limited to 698 MHz Canada Industry Canada RSS 123 IC 2099A SK9000 limited to 698 MHz Brazil QUANTA BRASIL IMPORTA O E EXPOR...

Страница 24: ...owing requirements Battery Directive 2006 66 EC The batteries or rechargeable batteries used can be recycled Please dispose of them as special waste or return them to your specialist dealer In order t...

Страница 25: ...d used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa tion If this e...

Страница 26: ...Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Publ 06 15 559420 A03...

Отзывы: