17
16
Accessoires
GZL 1019 A1 BNC/BNC co-axial cable
For connecting a radiator to the SI 1015, SI 29-5 or SI 1029 transmitters. Length: 1 m.
GZL 1019 A5 BNC/BNC co-axial cable
For connecting a radiator to the SI 1015, SI 29-5 or SI 1029 transmitters. Length: 5 m.
GZL 1019 A10 BNC/BNC co-axial cable
For connecting a radiator to the SI 1015, SI 29-5 or SI 1029 transmitters. Length: 10 m.
GZV 1019 BNC coupler
for connecting two GZL 1019 A1, -5, -10 co-axial cables.
GA 1031-AM blank module
For 19” rack mounting (with BNC sockets).
GA 1031-CC blank module
For 19” rack mounting.
For the AF connection, use a standard XLR-3 connection cable of the required length.
Note: “IR Planning Brochure” from Sennheiser
Information on the many possible areas of application of Sennheiser infra-red audio transmission
systems can be found in the “IR Planning Brochure”. This brochure gives detailed information on
infra-red transmission technology and contains application examples as well as possible product
combinations and overviews for infra-red system planning.
Since we are continually trying to improve our products it may happen that technical alterations
are made on the described products after this manual has gone to press. We apologise for any
inconvenience.
Technical Data
SI 1015
Modulator
Operating voltage
24 - 35 V DC (via NT 1015)
Current consumption
< 140 mA
Terminating impedance of the RF outputs
50
Ω
Carrier frequency 1
2.3 MHz
Carrier frequency 2
2.8 MHz
Inputs
2 x XLR-3, balanced
Input sensitivity
50 mV – 5 V
RF outputs
2 x BNC, in parallel with
barrier strip
SZI 1015
Power radiator
Number of transmitting diodes
66
Average radiating power
2 W
Wavelength of radiated infra-red light
approx. 880 nm
Carrier frequency range
30 kHz – 6 MHz
RF input level
50 mV – 3 V / approx. 5 k
Ω
Inputs / outputs
BNC sockets / barrier strip
Threshold voltage for
automatic on/off function
50 mV
Operating voltage
25–35 V DC via NT 1015 plug-in mains unit
or via SI 1015 modulator
Current consumption
0.75 A at 25 V
Stand-by
max. 60 mA
Dimensions in mm
approx. 250 x 100 x 80
Weight
approx. 1.3 kg
NT 1015
Plug-in mains unit
Mains voltage
100 – 240 V AC without switching
Output voltage
29 V DC
Output current
1.7 A, for powering an SI 1015 modulator
and two SZI 1015 power radiators or an
SI 1015 modulator and one SZI 1029-24
high power radiator
Содержание SI 1015
Страница 6: ...11 10 SI 1015 SZI 1015 INSTRUCTIONS FOR USE ...
Страница 10: ...19 18 SI 1015 SZI 1015 NOTICE D EMPLOI ...
Страница 14: ...27 26 SI 1015 SZI 1015 ISTRUZIONI PER L USO ...
Страница 18: ...35 34 SI 1015 SZI 1015 INSTRUCCIONES PARA EL USO ...
Страница 22: ...43 42 SI 1015 SZI 1015 GEBRUIKSAANWIJZING ...