background image

10 

Using the operating menu

Using the operating menu 

A special feature of the Sennheiser ew G3 series is the consistent, intuitive
menu structure of transmitters and receivers. As a result, adjustments to
the settings can be made quickly – even in stressful situations, for example
on stage or during a live show or presentation.

The buttons

Overview of the operating menu

Button

Function of the button

Press the 

ON

/

OFF

 button

• Switches the plug-on transmitter on and 

off

• Cancels the entry and returns to the 

current standard display (ESC function)

• Activates/deactivates the RF signal 

(special function, see page 8)

Press the 

SET

 button

• Changes from the current standard display 

to the operating menu

• Calls up a menu item

• Enters  a  submenu

• Stores the settings and returns to the 

operating menu

Press the UP/DOWN 
button

• Selects a standard display

• Changes to the next/previous menu item

• Changes the setting of a menu item

Display

Function of the menu item

Page

Main menu “Menu”

Sensitivity

Adjusts the sensitivity “

AF

13

Frequency Preset

Sets the frequency bank and the channel

13

Name

Enters a freely selectable name

14

Auto Lock

Activates/deactivates the automatic lock 
mode

14

Advanced

Calls up the extended menu 

Advanced Menu

15

Exit

Exits the operating menu and returns to the 
current standard display

Extended menu “Advanced Menu”

Tune

Sets the transmission frequencies for the 
frequency bank “

U

15

Sets a channel and a transmission frequency 
for the frequency bank “

U

15

Mute Mode

Sets the mode for the 

MUTE

 switch

16

Pilot Tone

Activates/deactivates the pilot tone 
transmission

16

ON/OFF

SET

Main menu
“Menu”

Sensitivity

 

Frequency Preset
Name
Auto Lock

Advanced 

Exit

Tune
Mute Mode
Pilot Tone 

 

LCD Contrast 
Reset
Software Revision
Exit

Extended menu
“Advanced Menu”

All manuals and user guides at all-guides.com

all-guides.com

Содержание EW 100 G3

Страница 1: ...SKP 100 Instruction manual All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...signal 8 Selecting a standard display 9 Using the operating menu 10 The buttons 10 Overview of the operating menu 10 Working with the operating menu 11 Adjusting settings via the operating menu 13 The...

Страница 3: ...or moisture does not operate properly or has been dropped WARNING To reduce the risk of short circuits do not use the product near water and do not expose it to rain or moisture Replacement parts Whe...

Страница 4: ...e after switch on several transmission systems can be operated simultaneously on the preset frequencies without causing intermodulation interference The frequency bank system The plug on transmitter i...

Страница 5: ...be downloaded from the SKP 100 G3 product page on our website at www sennheiser com The frequency bank U allows you to freely select and store transmission frequencies It might be that these transmis...

Страница 6: ...n and battery status indicator red LED lit ON flashing LOW BATTERY ON OFF button with ESC function cancel MUTE switch SET button Battery compartment cover Display Meaning Audio level AF Modulation of...

Страница 7: ...compartment The battery compartment cover locks into place with an audible click Charging the accupack Remove the BA 2015 accupack Insert the BA 2015 accupack into the L 2015 charger see Accessories...

Страница 8: ...FF button The plug on transmitter transmits an RF signal The red ON LED lights up and the Frequency Name standard display appears on the display panel The transmission icon is displayed You can switch...

Страница 9: ...transmission icon is displayed again Press the ON OFF button Locked appears on the display panel Press the UP button Unlock appears on the display panel Press the SET button The lock mode is temporar...

Страница 10: ...is displayed transmission icon is not displayed RF signal is activated MUTE is not displayed transmission icon is displayed You can also deactivate the RF signal on switch on For more information refe...

Страница 11: ...cts a standard display Changes to the next previous menu item Changes the setting of a menu item Display Function of the menu item Page Main menu Menu Sensitivity Adjusts the sensitivity AF 13 Frequen...

Страница 12: ...with the operating menu see page 8 Press the SET button The current standard display is replaced by the main menu The last selected menu item is displayed Press the UP DOWN button to change to the Se...

Страница 13: ...ent standard display Change to the Exit menu item Confirm your selection You return to the next higher menu level or you exit the operating menu and return to the current standard display Press the ON...

Страница 14: ...loud voices or loud music passages cause overmodulation in the transmission link The audio level display AF shows full deflection for the duration of the overmodulation correctly The audio level disp...

Страница 15: ...ormation on how to use the lock mode refer to page 8 Frequency bank Channels Type 1 to 20 up to 12 per frequency bank System bank frequencies are factory preset U up to 12 User bank frequencies are fr...

Страница 16: ...y bank U are not assigned a transmission frequency When you are in the Tune menu item the RF signal is deactivated It is vital to observe the notes on frequency selection on page 17 Press the UP DOWN...

Страница 17: ...ilot tone and for the frequency bank U remain unchanged For an overview of the factory preset default settings refer to the enclosed frequency information sheet Displaying the software revision Softwa...

Страница 18: ...ame frequency bank and the same channel as the receiver see page 13 If you still cannot establish a transmission link refer to the chapter If a problem occurs on page 19 Synchronizing plug on transmit...

Страница 19: ...vary from about 10 m to about 150 m There should be a free line of sight between plug on transmitter and receiving antennas To avoid overloading the receiver observe a minimum distance of 5 m between...

Страница 20: ...ot on the same channel Set the plug on transmitter to the same channel as the receiver Synchronize the plug on transmitter with the receiver see page 17 Transmissionrange is exceeded Reduce the distan...

Страница 21: ...wing SKP 100 G3 accessories are available from your specialist dealer Cat No Accessory 009950 BA 2015 accupack 009828 L 2015 charger 005232 POP 1 pouch with belt clip All manuals and user guides at al...

Страница 22: ...r system Sennheiser HDX AF frequency response 80 18 000 Hz Signal to noise ratio 1 mV RF peak deviation 110 dBA THD 0 9 Max input voltage 3 3 Vrms Input impedance 60 k unbalanced Adjustment range of i...

Страница 23: ...terference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are desi...

Страница 24: ...18 connecting microphones 6 D deactivating temporarily lock mode 8 displays adjusting the contrast of the display panel LCD Contrast 16 charge status 5 overview 5 standard displays 9 F factory default...

Страница 25: ...6 Tune setting a transmission frequency 15 using 11 P Pilot Tone activating deactivating the pilot tone transmission 16 plug on transmitter cleaning 18 switching on off 7 synchronizing with receiver 1...

Страница 26: ...ones de uso Sennheiser electronic GmbH Co KG Am Labor 1 30900 Wedemark Germany www sennheiser com Printed in Germany Publ 01 09 529675 A01 All manuals and user guides at all guides com a l l g u i d e...

Отзывы: