![Sennheiser EM 500 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/sennheiser/em-500/em-500_instruction-manual_1242400023.webp)
Using the receiver
22
Synchronizing a transmitter with the receiver
You can synchronize a suitable transmitter of the ew 500 G3 series with
the receiver. If the receiver is in ex works condition, the following parame-
ters are transferred to the transmitter during synchronization:
To transfer the parameters:
왘
Switch the transmitter and the receiver on.
왘
Press the
button
on the receiver.
“
Sync
” appears on the display panel of the receiver.
왘
Place the infra-red interface of the transmitter (see the instruction
manual of the transmitter) in front of the infra-red interface
receiver.
The parameters are transferred to the transmitter. When the transfer
is completed, “
” appears on the receiver’s display panel. The receiver
then switches back to the current standard display.
Setting
Transferred parameters
“
Frequency Preset
” Currently set frequency
“
Name
”
Freely selectable name currently set on the receiver
“
Pilot Tone
”
Current pilot tone setting of the receiver
(“
Inactive
”/“
Active
”)
Via the “
Sync Settings
” submenu, you can adjust the parameters to
be transferred to your transmitters (see page 41). It is vital to
observe the notes on frequency selection on page 45.
쐋
쐋
Содержание EM 500
Страница 1: ......