2.16
Technical data
Receiver EK 2013 PLL
Frequency range
EK 2013-6-D
8 m frequency band
36.64-37.98 MHz
EK 2013-6-1
8 m frequency band
30-36 MHz
EK 2013-6-2
8 m frequency band
35-40 MHz
EK 2013-6-3
8 m frequency band
39-45 MHz
EK 2013-8
4 m frequency band
72.025-75.975 MHz
EK 2013-9
2 m frequency band
173.350-175.02 MHz
Frequency preparation
Phase Lock Loop (PLL) Technique, 16 channels
Modulation type
FM
Rated lift/peak lift
±
8 kHz /
±
12 kHz
Channel grid/switching band width
EK 2013-6-D
40 kHz / 2.34 MHz
EK 2013-6-1
40 kHz / 2 MHz
EK 2013-6-2
40 kHz / 2 MHz
EK 2013-6-3
40 kHz / 2 MHz
EK 2013-8
25 kHz / 4 MHz
EK 2013-9
25 kHz / 2 MHz
Sensitivity
(measured via artificial antenna)
typ. 0.5
µ
V for 26 dB S/N
Neighboring channel selection
typ. 70 dB
LF transmission range
40 - 16,000 Hz
Nonlinear distortion factor
at 1 kHz and rated lift
typ. 1 %
LF output 1:
3.5 mm dia. jack
High:
2 x 0.7 V / 32 U
LF output 2:
2.5 mm dia. jack
Low (hearing aids):
2 x 3 mV / 2 k
Ω
Impedance at LF output 2
for connection of hearing aids
in normal operation
3 k
Ω
with activated automatic fade-in
80 U to 1 kU adjustable
Operating voltage 2.4 V
Current consumption
approx. 45 mA
Operating time
> 14 hours with RECHARGEABLE battery
pack
BA 2013
> 40 hours with 2 x Alkaline AA cells in B 2013
Battery check
red LED for operating voltage < 2.2 V
Dimensions
18 x 58 x 95 mm
Weight (incl. B 2013)
approx. 130 g
German ZZF Certification No.
A 014 926 B ME (only -6)
Scope of delivery
1 Receiver EK 2013 PLL
1 Battery compartment B 2013
Not responsible for errors. Subject to change without notice.