Specifications
DW Series – Setup Guide
| 19
Power supply unit
DECT
In compliance with
USA & Canada:
This product meets the safety requirements of CSA No. 231437
Nominal input voltage
100 – 240 V~
Nominal input current
max. 0.2 A
Mains frequency
50 – 60 Hz
Nominal output voltage
5 V
Nominal output current
max. 850 mA
Operating temperature range +5°C to +45°C (+41°F to +113°F)
Storage temperature range
–20°C to +70°C (–4°F to +158°F)
Relative humidity
operation: 20 to 85%
storage: 20 to 95%
Weight
approx. 75 g
EU, UK, AU:
CAT IQ 1.0
US version:
DECT 6.0
Frequency
1,880 to 1,900 MHz 1,920 to 1,930 MHz
SAR value of DW Office – HS 0.196 W/kg
(max. 10 g SAR)
0.093 W/kg
(max. 1 g SAR)
SAR value of DW Pro1 – HS
0.069 W/kg
(max. 10 g SAR)
0.044 W/kg
(max. 1 g SAR)
SAR value of DW Pro2 – HS
0.058 W/kg
(max. 10 g SAR)
0.025 W/kg
(max. 1 g SAR)
Europe:
EMC
EN 301489-6
Radio
EN 301406
Safety
EN 60950-1
SAR
EN 50360 ref
EN 62209-1
(headset)
Canada:
IC: 2099D-TDB1
(DW BS-US & DW BS USB-US)
IC: 2099D- TDH1
(DW 10 HS/DW 20 HS/DW 30 HS)
IC: 2099D-TDH1
IC: 2099D-TDH1
USA:
FCC ID: DMOCDBDIB (DW BS-US)
FCC ID: DMOCDBDKB (DW BS USB-US)
FCC ID: DMOCDHDFC
FCC ID: DMOCDHDEC