SENKO pellet SLIM MODERN stoves
–
Instruction manual
48
The room temperature is measured by a probe (
P
-
figure 28
)
– black
wire, situated on the stove backside, next to the activation switch. In order
to more realistic room temperature measuring, it is necessary to
ensure
that the probe is located away from any heat influence
.
You can connect the stove also to the
room thermostat
. Thermostat
wires must be attached to the
"THERM" connection
on the back of the
stove. In this case the probe (
P
) at the back of the stove will no longer have
its function. The authorized individual must
activate the thermostat in the
technical menu
.
If your system is linked with a thermostat, instead the temperature icon
you’ll find the “Therm” icon. When the icon is red, means it’s closed contact,
otherwise when it’s white means open contact.
P
THERM
Figure 28