SYSTEM FILLING
The boiler is filled with water via valve R1/2'' located beneath the left side
panel.
Continuous circulation of water through the boiler
must be
ensured. The boiler must be
well deaerated prior to operations
commencement.
During filling, any air in the system is released from the
automatic vent valve
located at the highest point of the boiler, beneath the
left side panel.
The
filling pressure
of the boiler
WHEN COLD
must be
1 bar
.
For proper operation of the stove
WHEN HOT
, the pressure in the boiler
must be
1,5 bar
.
To monitor the system pressure (and temperature), the central
heating system must be fitted with thermo-manometer.
4.6.1. INSTALLATION TESTING
Prior to initial
firing
:
1.
It is necessary to
check if the boiler and the entire heating system
are filled with water and well deaerated
. Also
check if the smoke
uptake pipe is properly fastened,
2.
Activate the safety valve and check its proper functionality,
3.
Check the pump operation
(you can do this only if the stove is in OFF).
It is necessary to turn on the pump using the following steps on the
touch screen panel:
Main
Menu
Settings
Start Pump
0/1
1
.
If the pump doesn
’t work, the rotor is blocked. Switch off the power, remove
the right side wall, remove the pump head (unscrewing 4 screws), clean the
rotor, spin the shaft with a screwdriver, check the electrical connections of
the pump and deaerate the entire system. Check again the pump operation.
After initiation
make sure:
there is no leakage of any kind,
that the entire installation is deaerated,
that the water temperature in the boiler is increasing,
that boiler operations do not result in condensation in the chimney.
Repeat the entire inspection after several days of constant firing !
Содержание P 10 WATER+AIR Slim Modern
Страница 1: ...INSTRUCTION MANUAL SN EN 719 PELLET STOVES SLIM MODERN P 8 AIR 8 kW P 10 WATER AIR 12 kW...
Страница 14: ...SENKO pellet SLIM MODERN stoves Instruction manual 13 Figure 1a P 8 AIR SLIM MODERN...
Страница 15: ...SENKO pellet SLIM MODERN stoves Instruction manual 14 P 10 WATER AIR SLIM MODERN Figure 1b...
Страница 16: ...SENKO pellet SLIM MODERN stoves Instruction manual 15 4 INSTALLATION 4 1 RECOMMENDATIONS Figure 2...
Страница 71: ...SENKO pellet SLIM MODERN stoves Instruction manual 70 Figure 43 a b c d e f g h...