background image

      

 

SENKO cookers 2P extra rustik and glass 

– 

Instruction manual

 

 

32 

 

figure 19 

5.5. 

OVEN DOOR 

 
 

Oven door

 are removed as shown in the following figure : 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

Reverse the procedure to mount the door back !

 

 

 
 
 
 
 

WARNING!

  Always  make  sure  that  the  hinge  safeties  properly  fit  in 

their bearings prior and after the removal of door!  

 

Otherwise  they  might  suddenly  pop  out  during  door  removal  or 

mounting,  i.e.  the  hinge  might  suddenly  close  due  to  strong  springs, 

which might cause injuries ! 

 
 
 

 open the oven door all the 

way 

 move the safety all the way 

back on the left and right oven 
hinges 

 close the door halfway 

ensuring that the safeties 
lean against the door slits 

 lift the ajar door upwards for 

approx. 2 mm and lightly pull them 
towards yourself, inclining the door 
toward the cooker simultaneously 

 pull the door from the cooker 

hinge bearing 

Содержание 2P-EXTRA RUSTIK

Страница 1: ...Central heating COOKERS 2P extra rustik and 2P glass SN EN 04 14...

Страница 2: ...manufactured to its minutest details in order to fulfill your every need for functionality and safety This Instruction manual will teach you to operate your cooker properly so please read the manual c...

Страница 3: ...ROL 14 4 3 CONNECTING TO CHIMNEY 14 4 4 FRESH AIR VENTS 16 4 5 OVEN THERMOMETER 17 4 6 CENTRAL HEATING SYSTEM CONNECTION 17 4 6 1 COOKER THERMAL PROTECTION 19 4 6 1 1 Thermal two way safety valve 20 4...

Страница 4: ...PERIOD 31 5 5 OVEN DOOR 32 6 CLEANING 33 6 1 CLEANING THE FLUE GAS CHANNEL 33 7 MAINTENANCE 34 7 1 AUTOMATIC REGULATOR 34 7 2 FIRING REGIME SWITCH MECHANISM 36 7 3 OLD COOKER DISPOSAL 36 7 4 SPARE PAR...

Страница 5: ...his Manual The cooker is hot during operation and the use of protective heat insulated gloves is compulsory during handling Children and infirm individuals are not allowed to handle the cooker The ext...

Страница 6: ...ened in order to prevent tumbling or damages The standard delivered cooker set consists from cooker instruction manual chimney terminal extension 23 firing regime adjustment grate lifting spanner 24 c...

Страница 7: ...quettes energy content at approx 4 4 kWh kg 1 2 FEEDING manually when necessary we recommend the logs to be of 50 x 50 mm vertical cut up to 2 3 of the firebox length use smaller logs for a more inten...

Страница 8: ...t in a manner which allows easy access and inspection via impermeable door 1 3 1 CHIMNEY CAP Chimney cap must fulfill the following prerequisites identical internal cross section to that of the chimne...

Страница 9: ...ence between the flue gases and the outer chimney air there is another type of pressure wind dynamic pressure Roof slope Distance between the roof ridge and the chimney Minimum chimney height measured...

Страница 10: ...derpressure pressure both inside and outside the residential area figure 4 Pressure that facilitates chimney function can occur in rooms directly exposed to the wind B but it can also adversely affect...

Страница 11: ...egulations Prior to use verify with the local authorized chimney sweeper whether the cooker is properly connected to the chimney the chimney sweeper must complete the installation report at the end of...

Страница 12: ...lined with chamotte and chamotte plates Exterior plates can consist of ceramic tiles or tempered glass in different colours The ash box 14 is on the frontal side at the bottom above it is the seconda...

Страница 13: ...ection point of the boiler thermal protection 20 R3 4 two way safety valve connection point of the boiler thermal protection see page 20 i e boiler thermal protection safety valve probe see pgs 21 22...

Страница 14: ...ts such as wood chipboard cork and similar If the materials are easily combustible such as PVC polyurethane and similar the necessary safety distances need to be doubled The minimum distance from any...

Страница 15: ...n provided by the chimney manufacturer e g for flue draught of 15 Pa the diameter is usually 160 mm The chimney must be smooth on the inside well insulated and well fastened All cleaning hatches must...

Страница 16: ...SENKO cookers 2P extra rustik and glass Instruction manual 15 figure 7 Differences between the proper and improper connection of the cooker to the chimney PROPER IMPROPER...

Страница 17: ...n diameter Specially designed sliding rosette enables the adjustment of the chimney opening in tolerance of 1 5 cm upwards i e downwards In case it is necessary to keep the cooker removed from the chi...

Страница 18: ...nd oven door The warranty will be void in case the damage to the parts listed before occurred from excessive oven temperature 4 6 CENTRAL HEATING SYSTEM CONNECTION Prior to commencing the firing proce...

Страница 19: ...thoroughly cleansed from potential filth sediments This prevents boiler overheating system noise pump malfunctions and mixing valve malfunctions The connection to the heating system is executed via un...

Страница 20: ...itions that will prevent boiler condensation Condensation may appear at the beginning of the firing process or due to insufficient feeding Pipeline thermostat which activates the circulation pump must...

Страница 21: ...kers 2P extra rustik and glass Instruction manual 20 4 6 1 1 THERMAL TWO WAY SAFETY VALVE figure 10 Orientational schematic for cooker connecting to a central heating system with a thermal two way saf...

Страница 22: ...rs 2P extra rustik and glass Instruction manual 21 4 6 1 2 THERMAL SAFETY VALVE figure 11 Orientational schematic for connecting the cooker to the central heating system with CALEFFI 544400 thermal sa...

Страница 23: ...2P extra rustik and glass Instruction manual 22 4 6 1 3 ANTI FREEZING PROTECTION figure 12 Orientational schematic for connecting the cooker to the central heating system with anti freezing protectio...

Страница 24: ...NKO cookers 2P extra rustik and glass Instruction manual 23 4 6 1 4 HEAT EXCHANGER Orientational schematic for connecting the cooker to the central heating system with a heat exchanger buffer figure 1...

Страница 25: ...unctionality 4 6 3 RECEIVING AND MAINTAINING THE INSTALLATION When receiving the installation inspect the installation in its entirety with the contractor The contractor is obligated to provide basic...

Страница 26: ...OVEN 5 HANDLING THE PRODUCT holding the cooker frame is not allowed while handling the appliance 5 1 DIRECTING THE FLUE GAS Flue gas deflector 17 accelerates the expulsion of flue gas from the cooker...

Страница 27: ...r 12 between the fuel box 15 and ash box 14 Its probe which measures the temperature of the water in the boiler is placed on the boiler frontal side under the lid between upper and lower door Turning...

Страница 28: ...ameter 100 mm The connecting pipe or the reduction must be made out of non flammable material in accordance with DIN 4102 B1 SECONDARY AIR Secondary air is the air that flows into the firebox to facil...

Страница 29: ...placed into the lower firebox position In C 20 2P cooker the grate is positioned via special mechanism summer regime the grate is elevated as necessary winter regime the grate is lowered Grate adjust...

Страница 30: ...e fire is in full flame add wooden logs as necessary close the flue gas deflector 17 regulate the fire intensity by regulating the volume of primary air via automatic regulator 12 primary air MUST NEV...

Страница 31: ...s may be achieved only if the cooker nominal power was chosen in accordance with the rules of profession and object energetic efficiency 5 4 3 ADDING FUEL Apart from use of appropriate fuel and satisf...

Страница 32: ...el combustion Once the fuel starts burning adjust the primary air automatic regulator 12 to a desired position in accordance with chapter 5 2 Flue gas deflector 17 MUST BE opened before opening the do...

Страница 33: ...erwise they might suddenly pop out during door removal or mounting i e the hinge might suddenly close due to strong springs which might cause injuries open the oven door all the way move the safety al...

Страница 34: ...be cleaned as necessary using the soot and grease cleaning agent 26 The agent is delivered with the cooker The oven 9 should be cleaned after every instance of use 6 1 CLEANING THE FLUE GAS CHANNEL Wh...

Страница 35: ...ring bolt on upper and lower doors and firebox door protective bolt to be tightened if necessary 7 1 AUTOMATIC REGULATOR When replacing the automatic regulator adhere to the following procedure remove...

Страница 36: ...oker maximum allowed probe temperature is 90 C The warranty is void if the probe temperature exceeds the maximum value installation of a new regulator is executed by reversing the procedure however sp...

Страница 37: ...rotective sheet above the mechanism first and then by removing the 4 frontal screws 4 rear end screws and 2 screws on each left and right sides all using an OK10 wrench and finally by removing the ent...

Страница 38: ...ring the summer period the boiler is not connected to the water heating boiler the cooker is not placed in a horizontal position with the use of spirit level excessive velocity of water flow in the sy...

Страница 39: ...r flow fuel too moist boiler damaged insufficient fuel quantity insufficient primary air volume reduce the water flow use fuel as described in chapter 1 1 call an authorized maintenance technician add...

Страница 40: ...between the grate and the boiler nails and similar malformed boiler thoroughly clean the non combustible material debris call an authorized maintenance technician 9 TECHNICAL SUPPORT Dear client If y...

Страница 41: ...Cooking plate W D mm 595 465 595 595 Cooking plate area m 2 0 276 0 354 Oven width mm 330 Oven height mm 220 Oven depth mm 440 550 Ash pan L 7 5 10 5 Fuel box L 31 6 Flue gases exhaust mm 150 Flue gas...

Страница 42: ...manufacturer Should the repairs not be executed within 30 days from the delivery to the manufacturer the product will be replaced with a new one The manufacturer will notify the client about the exec...

Страница 43: ...________________________ WARRANTY Faulty product date of receipt ___________________________ Malfunction description client ___________________________ ___________________________ ____________________...

Страница 44: ...ctions Central heating system connection executed by the company Company Business ____________ Person in charge ________________ Street ________________________ City _______________________ Telephone...

Страница 45: ...ter pressure 3 bar Flue gases temperature 270 C Heat output water 20 kW Heat output space 15 kW Efficiency 75 5 Fuel type wood wood briquettes Fuel consumption 10 kg h Certificate No E 30 00435 12 Rea...

Страница 46: ..._____________________________ ____________________________________________________________ ____________________________________________________________ ________________________________________________...

Страница 47: ...SENKO kamini Uputstvo za upotrebu 5...

Страница 48: ...Fax 385 0 40 337 906 E Mail info senko hr THE SPIRIT OF TRADITION IN MODERN FORMS FOR A HEALTHY ENVIRONMENT You can find this Manual at http en senko hr If you have any suggestions on how to improve t...

Отзывы: