A word about Dual Lock

®

fastener

According to the manufacturer, if Dual Lock

®

fastener is used properly it can withstand up
to 1,000 closures before replacement is
necessary. Inspect each piece of Dual Lock

®

fastener regularly and replace each piece at
the first sign of wear.

A piece of film covers the adhesive on the
back of each piece of Dual Lock

®

fastener 

(Figures 2 and 3)

. The adhesive is very

strong – it was manufactured for one mount
only so never reuse a piece of Dual Lock

®

fastener. If you remove a piece of Dual Lock

®

fastener from the mounting surface or
bracket, replace it with a new piece of Dual
Lock

®

fastener.

To remove Dual Lock

®

fastener:

The adhesive on Dual Lock

®

fastener bonds well enough to the

mounting surface that there is a possibility it may damage your wall
when you remove it. Gently grab a corner of the fastener and ease your
fingers under it. Roll the Dual Lock

®

fastener slowly off the mounting

surface.

Wheelchair and door applications

Your TABS

®

mobility monitor can also be used to monitor a person in a

wheelchair or to monitor an interior door. Contact your TABS
Representative to obtain the Wheelchair Bracket Assembly (Model
25100) or Easy-Clip Wheel Chair Bracket (Model 25300) or the Door
Mount Kit (Model 24010).

Connecting optional plug-in power supply for the TABS Professional

Insert plug-in power supply into power supply jack on left side of unit

(Figure 4a)

. The red indicator light on the front of the case will be on

when the unit is connected to the plug-in power supply.

protective

film (remove)

Dual Lock fastener

Figure 2

Figure 3

8

Содержание TABS 24010

Страница 1: ...25 00 6 A A PAT ENT PEN DIN G TEN T PEN DIN G Thi s pro duc t is ma nuf act ure d for Se nio r Tec hno log ies Inc by _____ _____ _____ _______________________ _______________________ DA TE PU T IN U...

Страница 2: ...D HCQ 3B6UMXF Canada 2309 101 597 This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this de...

Страница 3: ...al 10 Local alarm on off 11 Nurse call interface 12 Voice alarm Voice Professional 14 Voice options Voice Professional 15 Inserting and removing the monitor 15 Deterring removal of the TABS unit from...

Страница 4: ...llows Do not place items on the bed chair or monitoring location that may interfere with the cord assembly Use the proper length of TABS cord Using a length outside the caregiver s predetermined safet...

Страница 5: ...or use with TABS monitors only Do not substitute any other fall monitoring devices Keep the pressure pads flat at all times If the pressure pad is folded it may not function properly Do not use the pr...

Страница 6: ...or a nurse call cord to the proper jack will cause improper operation of the monitor The TABS Sidekick pressure pads are designed to withstand normal wear and tear for a period of 90 days or 1 year de...

Страница 7: ...division of Senior Technolog ies Inc For Customer Service call 800 824 2 996 DOC 04 2 5005 AA PATENT PENDING This product is manufact ured for Senior Technolog ies Inc by TH IS S ID E U P DO NO T FO L...

Страница 8: ...lert All TABS monitors are equipped with a low battery alert an intermittent chirping sound which reminds you to replace the battery immediately Listen for the alert each time you use or test your mon...

Страница 9: ...flush with the mounting surface 5 Align the holes in the bracket to the holes you have drilled and attach the bracket using four of the 4 x 1 screws Mounting the bracket with Dual Lock fastener 1 Clea...

Страница 10: ...bonds well enough to the mounting surface that there is a possibility it may damage your wall when you remove it Gently grab a corner of the fastener and ease your fingers under it Roll the Dual Lock...

Страница 11: ...ry snap gently as you attach the battery to the snap Do not pull on the wires Figure 4 4 The battery compartment was designed to hold the battery snugly in place Replace the battery so that the batter...

Страница 12: ...ry cover and test the unit The position of the number 1 and number 2 switches determines the tone The number 3 switch turns the local alarm on and off only available when using nurse call interface Th...

Страница 13: ...the monitor alarms for a period of seven minutes the local alarm will automatically turn on To set the nurse call only move the number 3 rocker switch to the right position If the cord is unplugged f...

Страница 14: ...nd of the cable with the 1 4 jack plug into the nurse call system wall jack If the plug does not fit the wall jack call TABS Customer Service at 800 824 2996 Note If the nurse call interface cord is n...

Страница 15: ...ts you connect the TABS chair or bed pad to the TABS monitor and your nurse call system Do not connect two pads to the T connector 1 Remove any cords that may be attached to the bottom of the TABS Sel...

Страница 16: ...shed recording The light will be on during this time indicating the monitor is recording Figure 9 3 Hold the monitor 8 12 from your mouth and record your message Speak slowly and enunciate your words...

Страница 17: ...ailure to do so may result in injury or death to a person in your care No device is a substitute for proper nursing care After the bracket has been mounted and your alarm options have been set insert...

Страница 18: ...nstalled remove it from the wall 2 Firmly hold the upper portion of the release tab with one hand 3 The release tab is scored with a mark Figure 11 Carefully position pliers along the lower side of th...

Страница 19: ...ured Attaching the clip Attach the clip securely to the person s garment at the top of the shoulder or close to the back of the neck Figure 13 Make sure the garment clip does not catch the person s sk...

Страница 20: ...at the first signs of wear or damage Troubleshooting the TABS mobility monitor If the alarm system is not triggered when the disk is pulled from the slot on the monitor Check the battery Is it install...

Страница 21: ...n conjunction with the TABS cord disk assembly the alarm sounds when the disk is pulled from the disk slot or when pressure is removed from the pressure pad whichever comes first The alarm is quickly...

Страница 22: ...Figure 15 TABS Professional Make sure that the disk or optional cordless reset is in the monitor s disk slot Plug the bed pressure pad cord into the right jack on the bottom of the TABS monitor Figure...

Страница 23: ...se and inspect the pressure pads and TABS monitor regularly to make sure they are not damaged Test the pressure pads by pressing firmly on the pressure pad for 3 seconds When you remove the pressure t...

Страница 24: ...he TABS unit Figure 20 An alarm will sound if a pad is plugged into the nurse call left jack and weight is applied to the pad 4 Mount the TABS unit on the wheelchair bracket Model 25100 or 25300 For p...

Страница 25: ...n you remove the pressure the alarm will sound Reset the alarm To reset the alarm 1 If you are using only the pressure pad reset the alarm by removing the disk or optional cordless reset and reinsert...

Страница 26: ...t sitting properly on the pressure pad If not reposition the pressure pad so that it is centered under the resident s body If using a TABS Professional monitor is the pressure pad connected to the jac...

Страница 27: ...monitor 25000 TABS Elite monitor 29700 Wheelchair bracket assembly and bungee cords 25100 Easy Clip Wheelchair bracket 25300 Wall mount bracket 25120 Nurse call interface cord 25150 Nurse call splitte...

Отзывы: